Absolute Maximum Rating (Ta = 25℃)

LED forward current30mA
LED forward current reduction rate-0.3mA/℃
LED reverse voltage5V
Connection temperature125℃
Load voltage (AC peak/DC)60V
Continuous load current (AC peak/DC)800mA
ON current reduction rate-8mA/℃
Pulse ON current2400mA
Connection temperature125℃
Dielectric strength between I/O500Vrms
Ambient operating temperature-40~+110℃
Ambient storage temperature-40~+125℃
Soldering temperature260℃

Electrical Characteristics (Ta=25℃)

LED forward voltage Minimum2.2V
LED forward voltage Typical2.42V
LED forward voltage Maximum2.8V
Capacitance between terminals15pF
Trigger LED forward current Maximum3mA
Release LED forward current Minimum0.1mA
Maximum resistance with output ON Typical0.4Ω
Maximum resistance with output ON Maximum0.8Ω
Current leakage when the relay is open Maximum1pA
Capacitance between terminals Typical38pF
Capacitance between terminals Maximum
Capacitance between I/O terminals1pF
Insulation resistance between I/O terminals Minimum1000MΩ
Insulation resistance between I/O terminals Typical108MΩ
Turn-ON time Typical0.75ms
Turn-ON time Maximum2.5ms
Turn-OFF time Typical0.04ms
Turn-OFF time Maximum0.5ms

*This page contains information excerpted from the product catalog. For other product information, please see the data sheet and other various data.