Absolute Maximum Rating (Ta = 25℃)

LED forward current30mA
Repetitive peak LED forward current1A
LED forward current reduction rate-0.3mA/℃
LED reverse voltage6V
Connection temperature125℃
Load voltage (AC peak/DC)60V
Continuous load current (AC peak/DC)3A
ON current reduction rate-30mA/℃
Pulse ON current9A
Connection temperature125℃
Dielectric strength between I/O2500Vrms
Ambient operating temperature-40~+110℃
Ambient storage temperature-55~+125℃
Soldering temperature260℃

Electrical Characteristics (Ta=25℃)

LED forward voltage Minimum1.5V
LED forward voltage Typical1.64V
LED forward voltage Maximum1.8V
Reverse current10μA
Capacitance between terminals70pF
Trigger LED forward current Typical0.3mA
Trigger LED forward current Maximum3mA
Release LED forward current Minimum0.1mA
Release LED forward current Typical0.2mA
Maximum resistance with output ON Typical45mΩ
Maximum resistance with output ON Maximum100mΩ
Current leakage when the relay is open Typical0.005μA
Current leakage when the relay is open Maximum1μA
Capacitance between terminals Typical250pF
Capacitance between I/O terminals0.8pF
Insulation resistance between I/O terminals Minimum1000MΩ
Insulation resistance between I/O terminals Typical10^8MΩ
Turn-ON time Typical0.45ms
Turn-ON time Maximum2ms
Turn-OFF time Typical0.2ms
Turn-OFF time Maximum1ms

*This page contains information excerpted from the product catalog. For other product information, please see the data sheet and other various data.