Absolute Maximum Rating (Ta = 25℃)

LED forward current30mA
LED forward current reduction rate-0.3mA/℃
LED reverse voltage5V
Connection temperature125℃
Load voltage (AC peak/DC)60V
Continuous load current (AC peak/DC)400mA
ON current reduction rate-4.0mA/℃
Pulse ON current1200mA
Connection temperature125℃
Dielectric strength between I/O1500Vrms
Ambient operating temperature-40~ +85℃
Ambient storage temperature-55~ +125℃
Soldering temperature260℃

Electrical Characteristics (Ta=25℃)

LED forward voltage Minimum1.1V
LED forward voltage Typical1.27V
LED forward voltage Maximum1.4V
Reverse current10μA
Capacitance between terminals30pF
Trigger LED forward current Typical-
Trigger LED forward current Maximum0.2mA
Release LED forward current Minimum-
Release LED forward current Typical0.001mA
Maximum resistance with output ON Typical
Maximum resistance with output ON Maximum
Current leakage when the relay is open Typical1nA
Current leakage when the relay is open Maximum1000nA
Capacitance between terminals Typical130pF
Capacitance between I/O terminals0.8pF
Insulation resistance between I/O terminals Minimum1000MΩ
Insulation resistance between I/O terminals Typical10^8MΩ
Turn-ON time Typical3.5ms
Turn-ON time Maximum10ms
Turn-OFF time Typical1ms
Turn-OFF time Maximum5ms

*This page contains information excerpted from the product catalog. For other product information, please see the data sheet and other various data.