What is the contact resistance of a basic switch?

ID: FAQE20018E

update:

Answer

The contact resistance is the resistance value (the initial resistance value is the CR before shipment) between the energized terminals when the contacts are in contact with each other. The resistance value of the contact area includes the conductor resistance of the spring and terminals.
The NC side (b-contact) is measured in the FP state and the NO side (a-contact) is measured in the TTP state.

Explanation

The contact resistance is the resistance value (the initial resistance value is the CR before shipment) between the energized terminals when the contacts are in contact with each other. The resistance value of the contact area includes the conductor resistance of the spring and terminals. The NC side (b-contact) is measured in the FP state and the NO side (a-contact) is measured in the TTP state.

Keep the following in mind to increase contact pressure:

  1. The larger the OF, the larger the contact pressure.
  2. The larger the OF, the larger the contact pressure.
  3. The contact pressure is higher at the FP and TTP points during the stroke.
    Please note that in particular, contact pressure becomes almost zero near the point of contact switching (OP point, RP point), causing contact instability and potential chattering.

F-S characteristic / CF-S characteristic

For more information, please see "Switch Basics" Technology / Operating Characteristics.

Quick tips

No Tips

Product category Switches Basic Switches
Classification Selection, Characteristics
Related keywords
  • Basic Switch
  • Contact Resistance
  • Unstable Contact
  • Oxidation
  • Sulfurization
  • Contact Pressure
  • F-S Characteristics
  • CF-S Characteristics

Related Questions

Q
Which basic switches have gold-plated contacts?
A
Gold contacts are mainly used in 0.1A rated Omron basic switches.
VX-01, D2MV-01, D2MC-01, D2VW-01
SS-01, D2S-01, D3M-01, D2SW-01, SS-01P, D2SW-P01
D2F-01, D2FD-01, D2HW, D2JW-01, D2FW-G01
Gold-plated sliding contact: D2QW-C0
Q
Which basic switches are suitable for microload?
A
Our basic switches with rated current of 0.1 A support microload.
Q
What is the sealing performance (waterproof, dustproof, gas resistance) of a basic switch?
A
Omron basic switches have a lineup of IP40 to IP67 protective structures with waterproof and dustproof specifications conforming to the protective structure. We have sealed basic switches with IP67. Please note that we do not have standards for gas resistance.