Which basic switches are inrush resistant?

ID: FAQE20008E

update:

Answer

The higher the rated current, the stronger the resistance to the inrush current. While the inrush current value is not described in the catalog, consider the rated current values.

Explanation

The inrush current varies depending on the conditions such as the time of application and the inrush state (when the contact is opened or closed, or when current is applied). Also, even if the current value is the same, the electrical life will differ depending on the operation speed and operation stroke. Please check the actual load switching of the equipment to be used.
There is also a TV rating (UL/CSA) for performance evaluation of inrush current, but we have no basic switch product that has obtained a TV rating.

For more details about inrush current, see "Switch Basics" Applications / Load Types & Ratings.

Quick tips

Omron has products with indium contacts that are resistive to arc heat. In some cases, actual load switching can be advantageous for DC switching that can easily cause inrush current or arc. Please evaluate them in an actual load switching test.
V-21-1C6 (IN)

Product category Switches Basic Switches
Classification Selection, Characteristics
Related keywords
  • Basic Switch
  • Inrush Current
  • TV Rating
  • UL/CSA
  • DC Switchingr

Related Questions

Q
Is it possible to use a product in DC that has only AC specification in the catalog?
A
In general, basic switches can be used in DC, but the electrical durability varies from product to product.Some models have reference evaluation data of switching capability. Please inquire individually.
Q
Does Omron have a small high-capacity snap-action switch?
A
Omron’s basic switch D2F is small sized and can be used for high-capacity switching.
Q
Which basic switches are heat resistant?
A
Omron has heat-resistant phenol resin type basic switches for V and SS.

If the information you are looking for is not found