Absolute Maximum Rating (Ta = 25℃)

LED forward current50mA
LED forward current reduction rate-0.5mA/℃
LED reverse voltage5V
Connection temperature125℃
Load voltage (AC peak/DC)350V
Continuous load current (AC peak/DC)150mA
ON current reduction rate-1.5mA/℃
Pulse ON current0.45A
Connection temperature125℃
Dielectric strength between I/O2500Vrms
Ambient operating temperature-40~+85℃
Ambient storage temperature-55~+125℃
Soldering temperature260℃

Electrical Characteristics (Ta=25℃)

LED forward voltage Minimum1.0V
LED forward voltage Typical1.15V
LED forward voltage Maximum1.3V
Reverse current10μA
Capacitance between terminals30pF
Trigger LED forward current Typical1mA
Trigger LED forward current Maximum3mA
Release LED forward current Minimum0.1mA
Maximum resistance with output ON Typical15Ω
Maximum resistance with output ON Maximum25Ω
Current leakage when the relay is open Maximum1μA
Capacitance between terminals Typical85pF
Capacitance between I/O terminals0.8pF
Insulation resistance between I/O terminals Minimum1000MΩ
Insulation resistance between I/O terminals Typical10^8MΩ
Turn-ON time Typical0.1ms
Turn-ON time Maximum1ms
Turn-OFF time Typical1ms
Turn-OFF time Maximum3ms