Absolute Maximum Rating (Ta = 25℃)

LED forward current30mA
Repetitive peak LED forward current1A
LED forward current reduction rate-0.3mA/℃
LED reverse voltage5VR
Connection temperature125℃
Load voltage (AC peak/DC)400V
Continuous load current (AC peak/DC)0.4A
ON current reduction rate-4mA/℃
Pulse ON current1.2A
Connection temperature125℃
Dielectric strength between I/O2500Vrms
Ambient operating temperature-40 ~ +85℃
Ambient storage temperature-55 ~ +125℃
Soldering temperature260℃

Electrical Characteristics (Ta=25℃)

LED forward voltage Minimum1.5V
LED forward voltage Typical1.64V
LED forward voltage Maximum1.8V
Reverse current10μA
Capacitance between terminals70pF
Trigger LED forward current Typical0.2mA
Trigger LED forward current Maximum1mA
Release LED forward current Minimum0.01mA
Release LED forward current Typical0.19mA
Maximum resistance with output ON Typical
Maximum resistance with output ON Maximum
Current leakage when the relay is open Typical0.001μA
Current leakage when the relay is open Maximum1μA
Capacitance between terminals Typical410pF
Capacitance between I/O terminals0.8pF
Insulation resistance between I/O terminals Minimum1000MΩ
Insulation resistance between I/O terminals Typical10^8MΩ
Turn-ON time Typical0.22ms
Turn-ON time Maximum1ms
Turn-OFF time Typical0.08ms
Turn-OFF time Maximum1ms