Absolute Maximum Rating (Ta = 25℃)

LED forward current50mA
Repetitive peak LED forward current1A
LED forward current reduction rate-0.5mA/℃
LED reverse voltage5V
Connection temperature125℃
Load voltage (AC peak/DC)600V
Continuous load current (AC peak/DC)100mA
ON current reduction rate-1.0mA/℃
Connection temperature125℃
Dielectric strength between I/O5000Vrms
Ambient operating temperature-40 ~ +85℃
Ambient storage temperature-55 ~ +125℃
Soldering temperature260℃

Electrical Characteristics (Ta=25℃)

LED forward voltage Minimum1V
LED forward voltage Typical1.15V
LED forward voltage Maximum1.3V
Reverse current10μA
Capacitance between terminals30pF
Trigger LED forward current Typical1.6mA
Trigger LED forward current Maximum5mA
Maximum resistance with output ON Typical30(25)Ω
Maximum resistance with output ON Maximum23Ω
Current leakage when the relay is open Maximum1μA
Capacitance between terminals Typical120pF
Capacitance between I/O terminals0.8pF
Insulation resistance between I/O terminals Minimum1000MΩ
Turn-ON time Typical0.2ms
Turn-ON time Maximum1.5ms
Turn-OFF time Typical0.2ms
Turn-OFF time Maximum1.0ms

*This page contains information excerpted from the product catalog. For other product information, please see the data sheet and other various data.