Absolute Maximum Rating (Ta = 25℃)

LED forward current50mA
LED forward current reduction rate-0.5
LED reverse voltage5V
Connection temperature150℃
Load voltage (AC peak/DC)1
800V
Continuous load current (AC peak/DC)30mA
ON current reduction rate-0.25mA/℃
Pulse ON current80mA
Connection temperature150℃
Dielectric strength between I/O5
000Vrms
Ambient operating temperature-40~+105℃
Ambient storage temperature-40~+125℃
Soldering temperature260℃

Electrical Characteristics (Ta=25℃)

LED forward voltage Minimum1.0V
LED forward voltage Typical1.33V
LED forward voltage Maximum1.5V
Reverse current5.0μA
Capacitance between terminals30pF
Trigger LED forward current Typical2mA
Trigger LED forward current Maximum5mA
Release LED forward current Minimum0.2mA
Maximum resistance with output ON Typical120Ω
Maximum resistance with output ON Maximum200Ω
Current leakage when the relay is open Maximum10(1)μA
Capacitance between terminals Typical10pF
Capacitance between I/O terminals1.3pF
Insulation resistance between I/O terminals Minimum10^9Ω
Turn-ON time Typical0.2ms
Turn-ON time Maximum1ms
Turn-OFF time Typical0.06ms
Turn-OFF time Maximum0.2ms

*This page contains information excerpted from the product catalog. For other product information, please see the data sheet and other various data.