Ultra-Compact DPDT Slim Relay,
Supports Area-Saving and High-Density Mounting Surface-Mounting Relay
G6J-Y

Contact Us
G6J-Y Relay
Product Features
01Reduces Component Count
Double-Pole, Double-Throw configuration enables multiple simultaneous switching with a single relay. It contributes to reducing the number of parts in equipment.

02 Contributes to Power Saving
Single winding coil latching type with a contact state holding function is also available, which contributes to power saving of equipment by reducing the control power of the relay.
03 Supports Mounting on Small Devices and High Integration
The extremely small mounting area contributes to mounting on small devices and high integration of boards.

G6J-Y Terminal
Types and Variations
-
G6J-2P-Y PCB terminals -
G6J-2FL-Y Surface-Mounting terminals,
long -
G6J-2FS-Y Surface-Mounting terminals,
short
Model Number Legend
- 1. Relay function None: Single-side stable relay
U: Single-winding latching relay - 2. Number of contact poles/ Contact form 2: 2-pole/DPDT (2c)
- 3. Terminal shape P: PCB terminals
FS: Surface-Mounting terminals, short
FL: Surface-Mounting terminals, long - 4. Special function Y: Improved product for soldering heat resistance
Ordering Information
Please swipe the table.
Packing | Tube packing | Tape packing | |||||||
---|---|---|---|---|---|---|---|---|---|
Relay function | Protective structure |
Contact form | Model | Rated coil voltage |
Minimun packing unit |
Model | Rated coil voltage |
Minimun packing unit |
Minimum ordering unit (tape packing) |
Single-side stable |
Fully sealed | DPDT | G6J-2P-Y | DC3 | 50 pcs/tube | - | DC3 | 400 pcs/reel | 800 pcs/ 2 reels |
DC4.5 | DC4.5 | ||||||||
DC5 | DC5 | ||||||||
DC12 | DC12 | ||||||||
DC24 | DC24 | ||||||||
G6J-2FS-Y G6J-2FL-Y |
DC3 | G6J-2FS-Y-TR G6J-2FL-Y-TR |
DC3 | ||||||
DC4.5 | DC4.5 | ||||||||
DC5 | DC5 | ||||||||
DC12 | DC12 | ||||||||
DC24 | DC24 | ||||||||
Single-winding latching |
G6JU-2P-Y | DC3 | - | DC3 | |||||
DC4.5 | DC4.5 | ||||||||
DC5 | DC5 | ||||||||
DC12 | DC12 | ||||||||
DC24 | DC24 | ||||||||
G6JU-2FS-Y G6JU-2FL-Y |
DC3 | G6JU-2FS-Y-TR G6JU-2FL-Y-TR |
DC3 | ||||||
DC4.5 | DC4.5 | ||||||||
DC5 | DC5 | ||||||||
DC12 | DC12 |
Similar Product Spec Comparison Table
Please swipe the table.
G6J-Y | G6S | ||||
---|---|---|---|---|---|
![]() |
![]() |
||||
Terminal shape | PCB terminals | Surface-Mounting | PCB terminals | Surface-Mounting | |
Contact form | 2c | 2c | |||
Rated load | AC125V 0.3A DC30V 1A |
AC125V 0.5A DC30V 2A |
|||
Max. switching current | 1A | 2A | |||
Dimensions | H(mm) | 9 | 10 | 9.2 | |
L(mm) | 10.6 | 14.8 | |||
W(mm) | 5.7 | 7.3 | |||
Power consumption (Single-side stable) |
140mW ~ 230mW | 140mW ~ 200mW | |||
Operating (set) time/Release (reset) time | 3ms max./3ms max. | 4ms max./4ms max. | |||
Insulation resistance | 1,000 MΩ min. | 1,000 MΩ min. | |||
Dielectric strength | Between coil and contacts | AC1,500V 1min | AC2,000V 1min | ||
Between contacts of different polarity | AC1,000V 1min | AC1,500V 1min | |||
Between contacts of the same polarity | AC750V 1min | AC1,000V 1min | |||
Mechanical durability | 50,000,000 operations min. | 100,000,000 operations min. | |||
Electrical durability | 100,000 operations min.(Rated load) | 100,000 operations min.(Rated load) | |||
Impulse withstand voltage | Between coil and contacts | 2,500V 2 x 10μs | 2,500V 2 x 10μs | ||
Between contacts of different polarity | 1,500V 10 x 160μs | 1,500V 10 x 160μs | |||
Between contacts of the same polarity | 1,500V 10 x 160μs | 1,500V 10 x 160μs | |||
Ambient operating temperature | -40 ~ +85℃ (with no icing or condensation) |
-40 ~ +85℃ (with no icing or condensation) |
|||
Ambient operating humidity | 5 ~ 85%RH | 5 ~ 85%RH | |||
Single-side stable | ● | ● | ● | ● | |
Single-winding latching | ● | ● | ● | ● | |
Double-winding latching | - | - | ● | ● |
You can check the technical details of the products from the following resources:
- G6J-Y Datasheet More Infomation
- G6S Datasheet More Infomation
G6J-Y Relay
Application Examples
5G Related

The next-generation communication standard "5G" has begun to be introduced in various devices including 5G base stations.
The G6J-Y contributes to the high integration of communication equipment such as Exchanges and Edge Routers, Ethernet Switches, and Set-Top Boxes.
Digital Switching System
Edge Router
Set Top Box
Smart Home Related

In smart home-related fields, G6J-Y can be used in a variety of devices, from Smart Meters, Thermostat Controllers, Security Devices to Digital Audio Players.
Smart Home
ControllerThermostat
ControllerSmart Meter
Digital Audio
PlayerSecurity Equipment
Other application examples
Home Appliances Air Conditioner (Outdoors) Indoor / outdoor unit standby power cut
Indoor / outdoor unit controlIndustrial Semiconductor Manufacturing Equipment Control board : Control signal switching
Industrial Machine Tool External output board : Switching I/O signals
Building Automation Access Control System TV doorphone : Switching between audio and image
Industrial Test and Measurement Equipment Measurement circuit: Switching singal
Building Automation Fire/Smoke/Gas Alarm System Detector : Alarm signal
Controller : Control signal switchingEnergy Power Conditioner for Solar Power Generation Power Conditioner : Operation signals, error signals