G6RL PCB Power Relays
Low-profile 12.3 mm height power relay with maximum switching of 10A
- Low profile: 12.3 mm in height
- Max. switching capacity: 2,500 VA (NO)
- Dielectric strength: 5 kV
- Clearance and creepage distance: 10 mm.
- Models for P1 load (2 × 200 W lamps parallel to ignition transformer) are available.
Classification | Enclosure rating | Contact form | Model | Rated coil voltage | Minimum packing unit | |
---|---|---|---|---|---|---|
Standard | Flux protection | SPST-NO(1a) | G6RL-1A-ASI | G6RL-1A | 3 VDC 5 VDC 6 VDC 12 VDC 24 VDC (48 VDC) ( ): Except -SR |
100 pcs/tray |
SPDT(1c) | G6RL-1-ASI | G6RL-1 | ||||
Fully sealed | SPST-NO(1a) | G6RL-1A4-ASI | --- | |||
SPDT(1c) | G6RL-14-ASI | --- | ||||
P1 Load | Flux protection | SPST-NO(1a) | G6RL-1A-ASI-PL | --- | ||
SPDT(1c) | G6RL-1-ASI-PL | --- | ||||
Shock resistance | Flux protection | SPST-NO(1a) | --- | --- | ||
SPDT(1c) | G6RL-1-SR-ASI | --- | ||||
Fully sealed | SPST-NO(1a) | --- | --- | |||
SPDT(1c) | G6RL-14-SR-ASI | --- |
Classification | Standard, P1 load(-PL type) | ||||||
---|---|---|---|---|---|---|---|
Rated voltage | 3 VDC | 5 VDC | 6 VDC | 12 VDC | 24 VDC | 48 VDC | |
Rated current | 73.3 mA | 44.0 mA | 36.7 mA | 18.3 mA | 9.2 mA | 5.0 mA | |
Coil resistance | 40 Ω | 113 Ω | 163 Ω | 654 Ω | 2,618 Ω | 9,600 Ω | |
Must operate voltage | % of rated voltage | 70% max. of rated voltage | |||||
Must release voltage | 10% min. of rated voltage | ||||||
Max. voltage | 150% of rated voltage (at 23°C) | ||||||
Power consumption | Approx. 220 mW | Approx. 240 mW |
Contact Ratings
Load | Resistive load (cos φ = 1) |
---|---|
Contacts type | Single |
Contacts material | Ag-alloy (Cd free) |
Rated load (see note 1.) | 10 A at 250 VAC, (NO) resistive load 8 A at 250 VAC, resistive load 5 A at 30 VDC, resistive load |
Rated carry current | 10 A |
Max. switching current | NO: 10 A, NC: 8 A |
note: | 1. | G6RL-1(A), G6RL-1(A)4-ASI: 8 A 250 VAC, resistive load; 5 A 24 VDC resistive load. |
Characteristics
Contact resistance (see note 1.) | 100 mΩ max. | |
---|---|---|
Operate time | 10 ms max. (SR Models: 15 ms max.) | |
Release time | 5 ms max. | |
Insulation resistance (see note 2.) | 1,000 MΩ min. | |
Dielectric strength | Between coil and contacts | 5,000 VAC, 50/60 Hz for 1 min |
Between contacts of the same polarity | 1,000 VAC, 50/60 Hz for 1 min | |
Impulse withstand voltage | Between coil and contacts | 10kV (1.2×50νs) |
Vibration resistance | Destruction | 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) |
Malfunction | 10 to 55 to 10 Hz, 0.825 mm single amplitude (1.65 mm double amplitude) when energized 10 to 55 to 10 Hz, 0.4 mm single amplitude (0.8 mm double amplitude) when de-energized. |
|
Shock resistance | Destruction | 1,000 m/s2 |
Malfunction | NO: 200 m/s2, NC: 50 m/s2 | |
Endurance (Mechanical) | Mechanical | 10,000,000 operations min. (at 18,000 operations/h) |
Electrical | G6RL-1(A) 50,000 operations min. (NO) at 250 VAC, 8A (resistive load) 50,000 operations min. (NC) at 250 VAC, 8A (resistive load) 50,000 operations min. at 24 VDC, 5A (resistive load) (at 600 operations/h) G6RL-1(A)-(SR)-ASI-(PL) 100,000 operations min. (NO) at 250 VAC, 10A (resistive load) 100,000 operations min. at 250 VAC, 8A (resistive load) 50,000 operations min. at 30 VDC, 5A (resistive load) (at 1,800 operations/h) G6RL-1(A)4-ASI 50,000 operations min. (NO) at 250 VAC, 8A (resistive load) 50,000 operations min. (NC) at 250 VAC, 8A (resistive load) 50,000 operations min. at 24 VDC, 5A (resistive load) (at 1,800 operations/h) |
|
Failure rate (P level) (reference value) (see note 3.) | 10 mA at 5 VDC | |
Ambient operating temperature | -40°C to 85°C (with no icing or condensation) | |
Ambient operating humidity | 5% to 85% | |
Weight | Approx. 7.8 g |
note: | The given values are initial values. |
1. | Measurement conditions: 5 VDC, 1 A, voltage drop method. |
2. | Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. |
3. | This value was measured at a switching frequency of 120 operations/min. |
Approved Standards
Creepage distance | 10 mm | |
---|---|---|
Clearance distance | 10 mm | |
Insulation material group | IIIa | |
Rated insulation voltage | 250 V | |
Pollution degree | 3 | 2 |
Rated voltage system | 250 V | 400 V |
Overvoltage category | III | II |
Tracking index of relay base | PTI 250 V min.(housing parts) | |
Flammability class according to UL94 |
V-0 | |
Ball pressure test (IEC 60695-10-2) |
170ºC |
G6RL-1A G6RL-1A-ASI G6RL-1A4-ASI |
|
G6RL-1 G6RL-1-ASI G6RL-14-ASI |
Correct Use
The G6RL are net intended to be used in automotive applications (including two wheel vehicles).
TIf the product is used in the following applications, consult your OMRON sales representative to check the necessary items according to the specification sheets. Also make sure the product is used within the specified ratings and performance ranges with an ample margin and implement safety measures, such as designing a safety circuit, to minimize danger should the product fail.
a. Outdoor use, uses involving potential chemical contamination or electrical interference.
b. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, safety equipment, and equipment that could present a risk to human life or body.
c. Equipment requiring a high level of reliability, such as gas, water, or electrical supply systems.