Standards Certification

Standards certification / conformity list

You can check a status of certification and conformity for each standard.

| Signal Relay | Power Relay | AC Power Latching Relay | General-purpose Relay | MOS FET Relay | Solid-state Relay |
| Power MOS FET Relay | DC Power Relay | Socket |

Signal Relay

 

Model Standard Contact Operating coil ratings Standard No. Contact ratings
G5V-1 UL Approved Models (Recognized)  SPDT(1c) 3~24V DC  E41515 0.5A 125V AC(General Use) 40℃
1A 30V DC(Resistive) 40℃
0.3A 110V DC(Resistive) 40℃ 
CSA Approved Models (Certified) SPDT(1c) 3~24V DC  LR31928 0.5A 125V AC(General Use) 40℃
1A 30V DC(Resistive) 40℃
0.3A 110V DC(Resistive) 40℃ 
G5V-1-T90 UL Approved Models (Recognized)  SPDT(1c) 5~24V DC  E41515 0.5A 125V AC(Resistive) 90℃
1A 30V DC(Resistive) 90℃ 
CSA Approved Models (Certified) SPDT(1c) 5~24V DC  LR31928 0.5A 125V AC(Resistive) 90℃
1A 30V DC(Resistive) 90℃ 
G5V-2 UL Approved Models (Recognized)  DPDT (2c) 3~48V DC  E41515 0.6A 125V AC(General Use) 40℃
2A 30V DC(Resistive) 40℃
0.6A 110V DC(Resistive) 40℃ 
CSA Approved Models (Certified) DPDT (2c) 3~48V DC  LR31928 0.6A 125V AC(General Use) 40℃
2A 30V DC(Resistive) 40℃
0.6A 110V DC(Resistive) 40℃ 
G5V-2-H1 UL Approved Models (Recognized)  DPDT (2c)  3~48V DC  E41515 0.5A 125V AC(General Use) 40℃
0.2A 110V DC(Resistive) 40℃
2A 24V DC(Resistive) 40℃ 
CSA Approved Models (Certified) DPDT (2c) 3~48V DC  LR31928 0.5A 125V AC(General Use) 40℃
0.2A 110V DC(Resistive) 40℃
2A 24V DC(Resistive) 40℃ 
G6E UL Approved Models (Recognized)  SPDT(1c) 5~48V DC  E41515 0.2A 250V AC(General Use) 40℃
0.6A 125V AC(General Use) 40℃
2A 30V DC(Resistive) 40℃
0.6A 125V DC(Resistive) 40℃
CSA Approved Models (Certified) SPDT(1c) 5~48V DC  LR31928 0.2A 250V AC(General Use) 40℃
0.6A 125V AC(General Use) 40℃
2A 30V DC(Resistive) 40℃
0.6A 125V DC(Resistive) 40℃
G6A-274P-ST(15,40)-US
G6AK-274P-ST(40)-US
G6AU-274P-ST-US
UL/C-UL Approved Models (Recognized)  DPDT (2c) 3~48V DC  E41515 1A 125V AC(General Use) 40℃
2A 30V DC(General Use) 40℃ 
0.6A 110V DC(General Use) 40℃
G6S UL Approved Models (Recognized)  DPDT (2c) 3~24V DC  E41515 0.5A 125V AC(General Use) 40℃
0.3A 110V DC(General Use) 40℃
3A 30V DC(General Use) 40℃
CSA Approved Models (Certified) DPDT (2c) 3~24V DC  LR31928 0.5A 125V AC(General Use) 40℃
0.3A 110V DC(Resistive) 40℃
3A 30V DC(Resistive) 40℃ 
G6S(U)-2(F/G)-Y EN62368-1 Approved Models
(BSI Approved) (Certified)
DPDT (2c) 3~24V DC  VC657351 -
G6J-2P(FS/FL)-Y
G6JU-2P(FS/FL)-Y
UL/C-UL Approved Models (Recognized)  DPDT (2c) 3~24V DC  E41515 1A 30V DC(General Use) 40℃
0.5A 60V DC(General Use) 40℃
0.3A 125V AC(General Use) 40℃ 
G6K-2G(F/P) UL Approved Models (Recognized)  DPDT (2c) 3~24V DC  E41515 1A 30V DC(General Use) 40℃
0.5A 60V DC(General Use) 40℃
0.3A 125V AC(General Use) 40℃ 
CSA Approved Models (Certified) DPDT (2c) 3~24V DC  LR31928 1A 30V DC(Resistive) 40℃
0.5A 60V DC(Resistive)  40℃
0.3A 125V AC(General Use) 40℃ 
EN62368-1 Approved
Models
(BSI Approved)
(Certified)
DPDT (2c) 2 3~24V DC  VC689955 -
G6K(U)-2G(F/P)-Y UL Approved Models (Recognized)  DPDT (2c) 3~24V DC  E41515 1A 30V DC(General Use) 40℃
0.5A 60V DC(General Use) 40℃
0.3A 125V AC(General Use) 40℃ 
CSA Approved Models (Certified) DPDT (2c) 3~24V DC  LR31928 1A 30V DC(Resistive) 40℃
0.5A 60V DC(Resistive)  40℃
0.3A 125V AC(General Use) 40℃ 
EN62368-1 Approved
Models
(BSI Approved)
(Certified)
DPDT (2c) 3~24V DC  VC689955 ―― 

| Signal Relay | Power Relay | AC Power Latching Relay | General-purpose Relay | MOS FET Relay | Solid-state Relay |
| Power MOS FET Relay | DC Power Relay | Socket |

Power Relay

 

Model Standard Contact Operating coil ratings Standard No. Contact ratings
G5NB-1A(4)(-HA)(-CF)(-PW) UL Approved Models (Recognized)  SPST-NO (1a) 5~24V DC  E41515(UL508) 3A 250V AC(Resistive) 85℃
3A 30V DC(Resistive)70℃ 
CSA Approved Models (Certified) SPST-NO (1a) 5~24V DC LR31928(CSAC22.2
(No.0、No.14))
3A 250V AC(Resistive) 85℃
3A 30V DC(Resistive) 70℃
VDE Approved Models SPST-NO (1a) 5、12、18、24V DC  137575(EN61810-1) 3A 250V AC(cosφ=1.0) 85℃ 3A 30V DC(L/R=0ms)85℃ 
G5NB-1A(4)-E
G5NB-1A-E-HA
UL Approved Models (Recognized)  SPST-NO (1a) 5~24V DC  E41515(UL508) 5A 250 V AC (Resistive) 85°C
5A 30 V DC (Resistive) 70°C
CSA Approved Models (Certified) SPST-NO (1a) 5~24V DC LR31928(CSAC22.2
(No.0、No.14))
5A 250 V AC (Resistive) 85°C
5A 30 V DC (Resistive) 70°C
VDE Approved Models SPST-NO (1a) 5、12、18、24V DC  137575(EN61810-1) 5A 250 V AC (Resistive) 85°C
5A 30 V DC (Resistive) 85°C
3A 250V AC (Resistive) 85°C
G5NB-1A4-EL-HA(-PW)
G5NB-1A-EL-HA-A85
UL Approved Models (Recognized)  SPST-NO (1a) 5~24V DC  E41515(UL508) 7A 250V AC(General Purpose) 85℃
5A 250V AC(General Purpose) 85℃
5A 30V DC(Resistive)85℃ 
CSA Approved Models (Certified) SPST-NO (1a) 5~24V DC LR31928(CSAC22.2
(No.14))
7A 250V AC(General Purpose) 85℃
5A 250V AC(General Purpose) 85℃
5A 30V DC(Resistive)85℃ 
VDE Approved Models SPST-NO (1a) 5、12、24V DC 137575(EN61810-1) 7A 250V AC(Resistive) 85℃
5A 30V DC(Resistive)85℃ 
G5SB-1(A)(4) UL Approved Models (Recognized)  SPST-NO (1a)
SPDT(1c)
12~24V DC  E41515(UL508) 5A 250V AC N.O. only(Resistive) 40℃
3A 125V AC N.O. only(Resistive) 40℃
5A 30V DC N.O. only(Resistive) 40℃
3A 250V AC N.C. only(Resistive) 40℃
2A 125V AC N.C. only(Resistive) 40℃ 
CSA Approved Models (Certified) SPST-NO (1a)
SPDT(1c)
12~24V DC LR31928(CSAC22.2
(No.14))
5A 250V AC N.O. only(Resistive) 40℃
3A 125V AC N.O. only(Resistive) 40℃
5A 30V DC N.O. only(Resistive) 40℃
3A 250V AC N.C. only(Resistive) 40℃
2A 125V AC N.C. only(Resistive) 40℃
VDE Approved Models SPST-NO (1a)
SPDT(1c)
12、24V DC  40003957
(EN61810-1)
5A(N.O)/3A(N.C) 250V AC 70℃
G5PZ-1A UL Approved Models (Recognized)  SPST-NO (1a) 5~24V DC E41515
(UL508)
16A 277V AC (Resistive) 70℃
CSA Approved Models (Certified) SPST-NO (1a) 5~24V DC LR31928
(CSAC22.2 (No.14))
16A 277V AC (Resistive) 70℃
VDE Approved Models SPST-NO (1a) 5、12、24V DC 40042966
(EN61810-1)
16A 250V AC (Resistive) 70℃
CQC Approved Models SPST-NO (1a) 5、12、24V DC CQC15002133270 16A 250V AC (cosφ=1) 70℃
G5PZ-1A-E UL Approved Models (Recognized)  SPST-NO (1a) 5~24V DC E41515
(UL508)
20A 277V AC (Resistive) 70℃
CSA Approved Models (Certified)  SPST-NO (1a) 5~24V DC LR31928
(CSAC22.2 (No.14))
20A 277V AC (Resistive) 70℃
TUV Approved Models SPST-NO (1a) 5、12、24V DC R50408241
(EN61810-1)
20A 250V AC (cosφ=1) 70℃
CQC Approved Models SPST-NO (1a) 5、12、24V DC CQC15002133270 20A 250V AC (cosφ=1) 70℃
G5Q-1(A)(4)(-HA)(-PW) UL Approved Models (Recognized)  SPST-NO (1a)
SPDT(1c)
5~24V DC  E41515(UL508) 10A 250V AC N.O. only(Resistive) 40℃
10A 30V DC N.O. only(Resistive) 40℃
4A 120V AC N.O. only(Resistive) 40℃
3A 250V AC N.C. only(Resistive) 40℃
3A 30V DC N.C. only(Resistive) 40℃ 
CSA Approved Models (Certified) SPST-NO (1a)
SPDT(1c)
 5~24V DC LR31928(CSAC22.2
(No.14))
10A 250V AC N.O. only(Resistive) 40℃
10A 30V DC N.O. only(Resistive) 40℃
4A 120V AC N.O. only(Resistive) 40℃
3A 250V AC N.C. only(Resistive) 40℃
3A 30V DC N.C. only(Resistive) 40℃ 
VDE Approved Models SPST-NO (1a)
SPDT(1c)
5、9、12、24V DC  40009467
(EN61810-1)
10A  making and 0A breaking, 250V AC
(cosφ=1) 105 ℃
5A making and 3A breaking, 30V
DC (0ms) 105℃
5A 250V AC (cosφ=1) (N.O.) 105℃
G5Q-14-EU
G5Q-1A4-EU
G5Q-1-UE(-HA)
G5Q-1A-EU(-HA)
UL Approved Models (Recognized)  SPST-NO (1a)
SPDT(1c)
5~24V DC  E41515(UL508) 10A 250V AC N.O. only(Resistive) 40℃
10A 30V DC N.O. only(Resistive) 40℃
4A 120V AC N.O. only(Resistive) 40℃
3A 250V AC N.C. only(Resistive) 40℃
3A 30V DC N.C. only(Resistive) 40℃ 
CSA Approved Models (Certified) SPST-NO (1a)
SPDT(1c)
 5~24V DC LR31928(CSAC22.2
(No.14))
10A 250V AC N.O. only(Resistive) 40℃
10A 30V DC N.O. only(Resistive) 40℃
4A 120V AC N.O. only(Resistive) 40℃
3A 250V AC N.C. only(Resistive) 40℃
3A 30V DC N.C. only(Resistive) 40℃ 
VDE Approved Models SPST-NO (1a)
SPDT(1c)
5、12、24V DC 40009467
(EN61810-1)
10A 250V AC(cosφ=1)(N.O.) 65℃
5A 30V DC(0ms)(N.O.) 65℃
3A 30V DC(0ms)(N.C.) 65℃
4A 250V AC (cosφ=1) (N.O.) 85℃ 
G5Q-1A-EL-HA-VH UL Approved Models (Recognized)  SPST-NO (1a) 5~24V DC E41515(UL508) 10A 250V AC Resistive 40℃
CSA Approved Models (Certified) SPST-NO (1a) 5~24V DC LR31928(CSAC22.2
(No.14))
10A 250V AC Resistive 40℃
VDE Approved Models SPST-NO (1a) 5、12、24V DC 40009467
(EN61810-1)
10A 250V AC (cosφ=1) 105℃
G5Q-1A4-EL2-HA UL Approved Models (Recognized)  SPST-NO (1a) 5~24V DC E41515(UL508) 5A 250V AC Resistive 85℃
TV-3 40℃
1A 120V AC 30A Inrush-max. 1 msec 85℃
CSA Approved Models (Certified) SPST-NO (1a) 5~24V DC LR31928(CSAC22.2
(No.14))
5A 250V AC Resistive 85℃
TV-3 40℃
1A 120V AC 30A Inrush-max. 1 msec 85℃
VDE Approved Models SPST-NO (1a) 5、12、24V DC 40009467
(EN61810-1)
5A 250V AC (cosφ=1) 85℃
Peak Inrush 30A / Break 1A 230V AC 85℃
G5Q-1A4-EL3-HA UL Approved Models (Recognized)  SPST-NO (1a) 5~24V DC E41515(UL508) 10A 250V AC Resistive 40℃
1/2HP 250V AC 40℃
1/6HP 125 VAC 40°C
CSA Approved Models (Certified) SPST-NO (1a) 5~24V DC LR31928(CSAC22.2
(No.14))
10A 250V AC Resistive 40℃
1/2HP 250V AC 40℃
1/6HP 125 VAC 40°C
VDE Approved Models SPST-NO (1a) 5、12、24V DC 40009467
(EN61810-1)
3 A 250 VAC (cosφ=0.4) 85°C
G6D( ) UL Approved Models (Recognized)  SPST-NO (1a) 5~24V DC  E41515(UL508) 5A 30V DC(Resistive)40℃
5A 250V AC(Resistive) 40
D150 Pilot Duty
1/10HP 120V AC
CSA Approved Models (Certified) SPST-NO (1a) 5~24V DC LR31928(CSAC22.2
(No.0、No.14))
5A 30V DC(Resistive) 40℃
5A 250V AC(Resistive) 40℃
D150(Pilot Duty)
1/10HP 120V AC 
TÜV Approved Models SPST-NO (1a) 5、12、24V DC  R50167084
(EN61810-1)
5A 250V AC(cosφ=1.0) 70℃
5A 30V DC(0ms) 40℃ 
G6DN-1A UL/C-UL Approved Models (Recognized)  SPST-NO (1a) 4.5~24V DC E41515(UL508) 5 A at 277 VAC (Resistive) 95°C
5 A at 30 VDC (Resistive) 90°C
1/10 hp 125 VAC 95°C
1/10 hp 277 VAC 95°C
D300 120 VAC/240 VAC 95°C
C300 120 VAC/240 VAC 95°C
R300 125 VDC/250 VDC 95°C
VDE Approved Models SPST-NO (1a) 4.5、5、12、24V DC 40042696
(EN61810-1)
5 A at 250 VAC (cosφ= 1.0) 90°C
5 A at 30 VDC (L/R = 0 ms) 90°C
G6DN-1A-L UL/C-UL Approved Models (Recognized)  SPST-NO (1a) 5~24V DC E41515(UL508) 5 A 250 VAC (Resistive) 95°C
2 A 250 VAC (General Use) 95°C
2 A 30 VDC (General Use) 95°C
1/10 hp 120 VAC 40°C
C300 120 VAC/240 VAC 95°C
D150 120 VAC 95°C
R150 125 VDC 95°C
VDE Approved Models SPST-NO (1a) 5、12、24V DC 40042696
(EN61810-1)
5 A 250 VAC (cosφ= 1.0) 90°C
2 A 250 VAC (cosφ= 0.4) 90°C
2 A 250 VAC (cosφ= 0.6) 90°C
5 A 30 VDC (L/R = 0 ms) 90°C
2 A 30 VDC (L/R = 7 ms) 90°C
G6B-1114P-US
G6B-1114P-FD-US
 
UL Approved Models (Recognized)  SPST-NO (1a) 3~24V DC  E41643(UL508) 5A 250V AC(General Use) 80℃
5A 30V DC(Resistive)80℃
1/8HP 250V AC 80℃
1/6HP 250V AC 80℃
CSA Approved Models (Certified) SPST-NO (1a) 3~24V DC LR31928(CSAC22.2
(No.0、No.14))
5A 250V AC(General Use) 80℃
5A 30V DC 80℃
360W 120V AC Tungsten 80℃
1/6HP 250V AC 80℃ 
TÜV Approved Models SPST-NO (1a) 5、6、12、24V DC R50158246
(EN61810-1)
G6B-1114P-US
5A 250V AC(cosφ=1.0) 70℃
2A 250V AC(cosφ=0.4) 70℃
5A 30V DC(L/R=0ms) 70℃
G6B-1114P-FD-US
3A 250V AC(cosφ=1.0) 70℃
3A 30V DC(L/R=0ms) 70℃
G6B-1174P-US
G6B-1174P-FD-US
UL Approved Models (Recognized)  SPST-NO (1a) 3~24V DC  E41643(UL508) 8A 277V AC(General Use) 80℃ 8A 30V DC(Resistive) 80℃
5A 250V AC(General Use) 80℃
5A 30V DC(Resistive)80℃
1/8HP 250V AC 80℃
1/6HP 250V AC 80℃
CSA Approved Models (Certified) SPST-NO (1a) 3~24V DC LR31928(CSAC22.2
(No.0、No.14))
8A 277V AC(General Use) 80℃
8A 30V DC (Resistive) 80℃
TÜV Approved Models SPST-NO (1a) 5、6、12、24V DC R50158246
(EN61810-1)
G6B-1174P-US
8A 250V AC(cosφ=1.0) 70℃
2A 250V AC(cosφ=0.4) 70℃
8A 30V DC(L/R=0ms) 70℃
G6B-1174P-FD-US
5A 250V AC(cosφ=1.0) 70℃
2A 250V AC(cosφ=0.4) 70℃
5A 30V DC(L/R=0ms) 70℃
G6B-2114P-US
G6B-2114P-FD-US
UL Approved Models (Recognized)  SPST-NO (1a)+SPST-NC (1b) 3~24V DC E41643(UL508) 5A 250V AC(General Use) 80℃
5A 30V DC(Resistive) 80℃ 
CSA Approved Models (Certified) SPST-NO (1a)+SPST-NC (1b) 3~24V DC LR31928(CSAC22.2
(No.0、No.14))
5A 250V AC(General Use) 80℃
5A 30V DC (Resistive) 80℃
TÜV Approved Models SPST-NO (1a)+SPST-NC (1b) 5、6、12、24V DC R50158246
(EN61810-1)
G6B-2114P-US
5A 250V AC(cosφ=1.0) 70℃
1.5A 250V AC(cosφ=0.4) 70℃
5A 30V DC(L/R=0ms) 70℃
G6B-2114P-FD-US
1.5A 250V AC(cosφ=0.4) 70℃
3A 30V DC(L/R=0ms) 70℃
G6B-2214P-US
G6B-2014P-US
G6B-2214P-FD-US
G6B-2014P-FD-US
UL Approved Models (Recognized) 
DPST-NO (2a)
DPST-NC (2b)
3~24V DC E41643(UL508) 5A 250V AC(General Use) 80℃
5A 30V DC(Resistive) 80℃ 
CSA Approved Models (Certified) DPST-NO (2a)
DPST-NC (2b)
3~24V DC LR31928(CSAC22.2
(No.0、No.14))
5A 250V AC(General Use) 80℃
5A 30V DC (Resistive) 80℃ 
TÜV Approved Models DPST-NO (2a)
DPST-NC (2b)
5、6、12、24V DC R50158246
(EN61810-1)
G6B-2214P-US、G6B-2014P-US
5A 250V AC(cosφ=1.0) 70℃
1.5A 250V AC(cosφ=0.4) 70℃
5A 30V DC(L/R=0ms) 70℃
G6B-2214P-FD-US, G6B-2014P-FD-US
1.5A 250V AC(cosφ=0.4) 70℃
3A 30V DC(L/R=0ms) 70℃
G6RN-1
G6RN-1A
UL Approved Models (Recognized)  SPST-NO (1a)
SPDT(1c)
5~24V DC E41515(UL508) 8A 250V AC(Resistive) 85℃ 
CSA Approved Models (Certified) SPST-NO (1a)
SPDT(1c)
5~24V DC LR31928(CSAC22.2
(No.0、No.14))
8A 250V AC(Resistive) 85℃ 
VDE Approved Models SPST-NO (1a)
SPDT(1c)
5、6、12、24V DC  6135(EN61810-1) 8A 250V AC(cosφ=1.0) 85℃ 
G6RL( ) UL/C-UL (CSA) Approved Models (Recognized) SPST-NO (1a)
SPDT(1c)
3~48V DC  E41643(UL508) 10A 250V AC(NO)(Resistive)85℃
8A 250V AC(Resistive) 85℃
5A 30V DC(Resistive) 85℃
2FLA 12LRA 250V AC 65℃
1/2HP 250V AC 85℃ 
VDE Approved Models SPST-NO (1a)
SPDT(1c)
3、5、6、12、24、48V DC  40021033
(EN61810-1)
10A 250V AC(cosφ=1.0)(NO) 85℃
8A 250V AC(cosφ=1.0) 85℃
5A 30V DC(0ms) 85℃ 
G5LE-1(A)(4) UL Approved Models (Recognized)  SPST-NO (1a)
SPDT(1c)
5~24V DC E41643(UL508) 10A 250V AC(General Use)40℃
8A 30V DC(Resistive) 40℃
TV-3 (N.O. only) 40℃
CSA Approved Models (Certified) SPST-NO (1a)
SPDT(1c)
5~24V DC LR31928(CSAC22.2No.14)) 10A 250V AC(General Use)40℃
8A 30V DC(Resistive) 40℃
TV-3 (N.O. only) 40℃
VDE Approved Models SPST-NO (1a)
SPDT(1c)
5、12、24V DC  6850(EN61810-1) 10A 250V AC(cosφ=1)85℃ 
TÜV Approved Models (Certified) SPST-NO (1a)
SPDT(1c)
5、12、24V DC  R50158258
(EN61810-1)
2.5A 250V AC(cosφ=0.4) 85℃
10A 250V AC(cosφ=1) 85℃
8A 30V DC(0ms)40℃ 
G5CA( ) UL Approved Models (Recognized)  SPST-NO (1a) 5~100V DC  E41515(UL508) 15A 125V AC(General Use)40℃
10A 250V AC(General Use)40℃
10A 30V DC(Resistive) 40℃ 
CSA Approved Models (Certified) SPST-NO (1a) 5~100V DC  LR31928(CSAC22.2
(No.14))
15A 125V AC(General Use)40℃
10A 250V AC(General Use)40℃
10A 30V DC(Resistive) 40℃ 
TÜV Approved Models SPST-NO (1a) 5、6、12、24、48V DC  R50214486
(EN61810-1)
15A 125V AC(cosφ=1.0) 85℃
10A 250V AC(cosφ=1.0) 85℃
10A 30V DC(0ms) 85℃ 
G6C-1( ) UL Approved Models (Recognized)  SPST-NO (1a) 3~24V DC  E41643(UL508) 10A 250V AC(General Use) 80℃
10A 30V DC(Resistive) 80℃
1/6HP 125V AC、1/4HP 125V AC 80℃
1/3HP 250V AC、1/4HP 250V AC 80℃
600W 120V AC(Tungsten) 80℃ 
CSA Approved Models (Certified) SPST-NO (1a) 3~24V DC  LR31928(CSAC22.2No.14) 10A 250V AC(General Use) 80℃
10A 30V DC(Resistive) 80℃
1/6HP 125V AC、1/4HP 125V AC 80℃
1/3HP 250V AC、1/4HP 250V AC 80℃
VDE Approved Models SPST-NO (1a) 3、5、6、12、24V DC  40014439
(EN61810-1)
10A 250V AC(cosφ=1.0)40℃
5A 250V AC(cosφ=0.4) 40℃ 
TÜV Approved Models SPST-NO (1a) 3、5、6、12、24V DC  R50158249
(EN61810-1)
10A 250V AC(cosφ=1.0) 40℃
5A 250V AC(cosφ=0.4) 40℃
10A 30V DC(0ms) 40℃ 
G6C-2( ) UL Approved Models (Recognized)  SPST-NO (1a)+SPST-NC (1b) 3~24V DC  E41643(UL508) 8A 250V AC(General Use) 80℃
8A 30V DC(Resistive) 80℃
1/6HP 125V AC、1/4HP 125V AC 80℃
1/4HP 250V AC 80℃
600W 120V AC(Tungsten) 
CSA Approved Models (Certified) SPST-NO (1a)+SPST-NC (1b) 3~24V DC  LR31928(CSAC22.2No.14) 8A 250V AC(General Use) 80℃
8A 30V DC (Resistive) 80℃
1/6HP 125V AC、1/4HP 125V AC 80℃
1/4HP 250V AC 80℃
VDE Approved Models SPST-NO (1a)+SPST-NC (1b) 3、5、6、12、24V DC  40014439
(EN61810-1)
7A 250V AC(cosφ=1.0) 40℃
3.5A 250V AC(cosφ=0.4) 40℃ 
TÜV Approved Models SPST-NO (1a)+SPST-NC (1b) 3、5、6、12、24V DC  R50158249
(EN61810-1)
8A 250V AC(cosφ=1.0) 40℃
3.5A 250V AC(cosφ=0.4) 40℃
8A 30V DC(0ms)40℃ 
G4W( ) UL Approved Models (Recognized) SPST-NO (1a) 6~100V DC E41643(UL508) 15A 24V DC(Resistive) 40℃
15A 250V AC(General Use) 40℃
TV-8 40℃ 1/2HP 125V AC 40℃
1HP 250V AC 40℃
3/4HP 240V AC 40℃
DPST-NO (2a) 15A 36V AC(Resistive) 40℃ 15A 250V AC(General Use) 40℃
TV-5(non seald type)40℃
1/4HP、1/3HP 125V AC 40℃
1/3HP、1/2HP 250V AC 40℃
3/4HP 240V AC 40℃
(AgInSn contact and non seald type)
CSA Approved Models (Certified) SPST-NO (1a) 6~100V DC LR31928(CSAC22.2No.14) 15A 250V AC(General Use) 40℃
15A 24V DC(Resistive) 40℃
TV-8 40℃
1HP 250V AC 40℃
3/4HP 240V AC 40℃
DPST-NO (2a) 10A 250V AC(General Use) 40℃
TV-5 40℃
1/2HP 250V AC 40℃
1/3HP 125V AC 40℃
15A 24V DC 40℃
VDE Approved Models SPST-NO (1a) 6、12、24、48、100V DC 132295
(EN61810-1)
15A 250V AC(cosφ=1.0)40℃
10A 250V AC(cosφ=0.4)40℃
15A 24V DC(0ms) 40℃
7.5A 24V DC(40ms) 40℃ 
DPST-NO (2a) 10A 250V AC(cosφ=1.0)40℃
7.5A 250V AC(cosφ=0.4) 40℃
10A 24V DC(0ms) 40℃
5A 24V DC(40ms) 40℃ 
TÜV Approved Models SPST-NO (1a) 6、12、24、48、100V DC R50121120
(EN61810-1)
15A 250V AC(cosφ=1.0)55℃
10A 250V AC(cosφ=0.4)55℃
15A 24V DC(0ms) 55℃
7.5A 24V DC(40ms) 55℃ 
DPST-NO (2a)  10A 250V AC(cosφ=1.0)55℃
7.5A 250V AC(cosφ=0.4) 55℃
10A 24V DC(0ms) 55℃
5A 24V DC(40ms) 55℃ 
G4A-1A( ) UL Approved Models (Recognized)  SPST-NO (1a) 5~100V DC  E41643(UL508) 20A 250V AC(Resistive) 40℃
15A 30V DC(Resistive) 40℃
23A 277V AC(General Use)40℃ 
CSA Approved Models (Certified) SPST-NO (1a) 5~100V DC  LR31928(CSAC22.2
(No.0、No.14))
20A 250V AC(Resistive) 40℃
15A 30V DC(Resistive) 40℃
23A 277V AC(General Use)40℃ 
VDE Approved Models SPST-NO (1a) 5、12、18、24V DC  107293(EN61810-1) 20A 250V AC(cosφ=1.0) 50℃ 
G2RL-1A(-PW1) UL Approved Models (Recognized)  SPST-NO (1a) 3~48V DC E41643(UL508) 12A 250V AC(General Use)40℃
12A 24V DC(Resistive) 40℃ 
CSA Approved Models (Certified) SPST-NO (1a) 3~48V DC LR31928(CSAC22.2
(No.0、No.14))
12A 250V AC(General Use)40℃
12A 24V DC(Resistive) 40℃ 
VDE Approved Models SPST-NO (1a) 5、12、24、48V DC  119650(EN61810-1) 12A 250V AC(cosφ=1.0) 85℃
12A 24V DC(L/R=0ms) 85℃
AC15:3A 240V AC Temperature
DC13:2.5A 24V D C、50ms Temperature
CQC Approved Models SPST-NO (1a) 5 to 48V CQC17002171904 12 A, 250 VAC (cosφ=1) at room temperature
12 A, 24 VDC (L/R=0 ms) at room temperature
G2RL-1A-E(-HA、-PW1) UL Approved Models (Recognized)  SPST-NO (1a) 3~48V DC  E41643(UL508) 16A 250V AC(General Use)40℃
16A 24V DC(Resistive) 40℃ 
CSA Approved Models (Certified) SPST-NO (1a) 3~48V DC LR31928(CSAC22.2(No.0、No.14)) 16A 250V AC(General Use)40℃
16A 24V DC(Resistive) 40℃ 
VDE Approved Models SPST-NO (1a) 5、12、24、48V DC 119650(EN61810-1) 16A 250V AC(cosφ=1.0) 85℃
16A 24V DC(L/R=0ms) 85℃
AC15:3A 240V AC (NO) Temperature、1.5A 240V AC (NC) Temperature
DC13:2.5A 24V DC(NO)、50ms Temperature
CQC Approved Models SPST-NO (1a) 5 to 48V CQC17002171904 16A, 250VAC (cosφ=1) at room temperature
16A, 24VDC (L/R=0 ms) at room temperature
G2RL-1A-E-ASI UL Approved Models (Recognized)  SPST-NO (1a) 3~48V DC E41643
(UL508)
16A 250VAC (Resistive) 85℃
TV-3 40℃
CSA Approved Models (Certified) SPST-NO (1a) 3~48V DC LR31928
(CSA C22.2
(No.0、No.14))
16A 250VAC (Resistive) 85℃
TV-3 40℃
VDE Approved Models SPST-NO (1a) 5、12、24、48V DC 119650
(EN61810-1)
16A 250VAC (cosφ=1) 85℃
CQC Approved Models SPST-NO (1a) 5 to 48V CQC17002171904 16A, 250VAC (cosφ=1) at room temperature
16A, 24VDC (L/R=0 ms) at room temperature
G2RL-1A-E-CV(-HA) UL Approved Models (Recognized)  SPST-NO (1a) 3~48V DC E41643
(UL508)
16A 250VAC (Resistive) 105℃
TV-3 40℃
CSA Approved Models (Certified) SPST-NO (1a) 3~48V DC LR31928
(CSA C22.2
(No.0、No.14))
16A 250VAC (Resistive) 105℃
VDE Approved Models SPST-NO (1a) 5、12、24、48V DC 119650
(EN61810-1)
16A 250VAC (cosφ=1.0) 105℃
CQC Approved Models SPST-NO (1a) 5 to 48V CQC17002171904 16A, 250VAC (cosφ=1) at room temperature
16A, 24VDC (L/R=0 ms) at room temperature
G2RL-1A-H
G2RL-1-H
UL Approved Models (Recognized)  SPST-NO (1a)
SPDT(1c)
3~48V DC E41643
(UL508)
10A 250V AC(General Use)40℃
10A 24V DC(Resistive) 40℃ 
CSA Approved Models (Certified) SPST-NO (1a)
SPDT(1c)
3~48V DC LR31928
(CSA C22.2
(No.0、No.14))
10A 250V AC(General Use)40℃
10A 24V DC(Resistive)40℃ 
VDE Approved Models SPST-NO (1a)
SPDT(1c)
5、12、24V DC 119650
(EN61810-1)
10A 250V AC(cosφ=1.0)85℃
10A 250V AC(cosφ=1.0)40℃
10A 24V DC(L/R=0ms)85℃
G2RL-1(-HA、-PW1) UL Approved Models (Recognized)  SPDT(1c) 3~48V DC E41643
(UL508)
12A 250V AC(General Use)40℃
12A 24V DC(Resistive) 40℃ 
CSA Approved Models (Certified) SPDT(1c) 3~48V DC LR31928
(CSA C22.2
(No.0、No.14))
12A 250V AC(General Use)40℃
12A 24V DC(Resistive) 40℃ 
VDE Approved Models SPDT(1c) 5、12、24、48V DC 119650
(EN61810-1)
12A 250VAC(cosφ=1.0) 85℃
12A 24VDC(L/R=0ms) 85℃
AC15:3A 240VAC Temperature
DC13:2.5A 24VDC、50ms Temperature
CQC Approved Models SPDT(1c) 5 to 48V CQC17002171904 12 A, 250 VAC (cosφ=1) at room temperature
12 A, 24 VDC (L/R=0 ms) at room temperature
G2RL-1-E(-HA, -PW1) UL Approved Models (Recognized)  SPDT(1c) 3~48V DC E41643
(UL508)
16A 250VAC(General Use)40℃
16A 24VDC(Resistive) 40℃ 
CSA Approved Models (Certified) SPDT(1c) 3~48V DC LR31928
(CSA C22.2
(No.0、No.14))
16A 250VAC(General Use)40℃
16A 24VDC(Resistive) 40℃ 
VDE Approved Models SPDT(1c) 5、12、24、48V DC 119650
(EN61810-1)
16A 250V AC(cosφ=1.0) 85℃
16A 24V DC(L/R=0ms) 85℃
AC15:3A 240V AC (NO) Temperature、1.5A 240V AC (NC) Temperature
DC13:2.5A 24V DC(NO)、50ms Temperature
CQC Approved Models SPDT(1c) 5 to 48V CQC17002171904 16 A, 250 VAC (cosφ=1) at room temperature
16 A, 24 VDC (L/R=0 ms) at room temperature
G2RL-1-E-ASI UL Approved Models (Recognized)  SPDT(1c) 3~48V DC E41643
(UL508)
16A 250VAC (Resistive) 85℃
TV-3 40℃
CSA Approved Models (Certified) SPDT(1c) 3~48V DC LR31928
(CSA C22.2
(No.0、No.14))
16A 250VAC (Resistive) 85℃
TV-3 40℃
VDE Approved Models SPDT(1c) 5、12、24、48VDC 119650
(EN61810-1)
16A, 250VAC(cosφ=1.0) 85℃
CQC Approved Models SPDT(1c) 5 to 48V CQC17002171904 16 A, 250 VAC (cosφ=1) at room temperature
16 A, 24 VDC (L/R=0 ms) at room temperature
G2RL-1A-E2-CV-HA UL Approved Models (Recognized)  SPST-NO (1a)  5~24V DC  E41643
(UL508)
23A, 250VAC(Resistive)105℃
CSA Approved Models (Certified) SPST-NO (1a)  5~24V DC  LR31928 23A, 250VAC(Resistive)105℃
TÜV Approved Models SPST-NO (1a)  5~24V DC  R50426950
(EN61810-1)
23A, 250VAC (cosφ=1) 105℃
CQC Approved Models SPST-NO (1a) 5~24V DC  CQC17002171904 23A, 250VAC (cosφ) 105°C
G2RL-2A(-HA、-PW1) UL Approved Models (Recognized)  DPST-NO (2a) 3~48V DC  E41643(UL508) 8A 277V AC(General Use) 40℃
8A 30V DC(Resistive) 40℃ 
CSA Approved Models (Certified) DPST-NO (2a) 3~48V DC  LR31928(CSAC22.2(No.0、No.14)) 8A 277V AC(General Use) 40℃
8A 30V DC(Resistive) 40℃
VDE Approved Models DPST-NO (2a) 5、12、24、48V DC  119650(EN61810-1) 8A 250V AC(cosφ=1.0) 85℃
8A 30V DC(L/R=0ms) 85℃
AC15:1.5A 240V AC Temperature
DC13:2A 30V DC、50ms Temperature
CQC Approved Models DPST-NO (2a) 5 to 48V CQC17002171904 8 A, 250 VAC (cosφ=1) at room temperature
8 A, 30 VDC (L/R=0 ms) at room temperature
G2RL-2(-HA、-PW1) UL Approved Models (Recognized)  DPDT (2c) 3~48V DC  E41643(UL508) 8A 277V AC(General Use) 40℃
8A 30V DC(Resistive) 40℃ 
CSA Approved Models (Certified) DPDT (2c) 3~48V DC  LR31928(CSAC22.2(No.0、No.14)) 8A 277V AC(General Use) 40℃
8A 30V DC(Resistive) 40℃ 
VDE Approved Models DPDT (2c) 5、12、24、48V DC  119650
(EN61810-1)
8A 250V AC(cosφ=1.0) 85℃
8A 30V DC(L/R=0ms) 85℃
AC15:1.5A 240V AC Temperature
DC13:2A 30V DC、50ms Temperature
CQC Approved Models DPDT (2c) 5 to 48V CQC17002171904 3 A, 250 VAC (cosφ=1) at room temperature
3 A, 30 VDC (L/R=0 ms) at room temperature
G2RL-2-ASI UL Approved Models (Recognized)  DPDT (2c) 3~48V DC  E41643(UL508) 8A 250V AC(Resistive) 85℃
8A 30V DC(Resistive) 85℃
CSA Approved Models (Certified) DPDT (2c) 3~48V DC  LR31928(CSAC22.2(No.0、No.14)) 8A 250V AC(Resistive) 85℃
8A 30V DC(Resistive) 85℃
VDE Approved Models DPDT (2c) 5、12、24、48V DC  119650
(EN61810-1)
8A 250V AC(Resistive) 85℃
8A 30V DC(Resistive)85℃
CQC Approved Models DPDT (2c) 5~48V DC CQC17002171904 3A 250V AC (cosφ=1) at room temperature
3A 30V DC (L/R=0ms) at room temperature
G5RL-1A-LN UL/C-UL Approved Models (Recognized)  SPST-NO (1a) 5~24V DC  E41643(UL508) 12A 250V AC(Resistive) 40℃
12A 24V DC(Resistive) 40℃
TV-5, 120 VAC, 40°C
VDE Approved Models SPST-NO (1a) 5、12、24V DC  40007172
(EN61810-1)
12A 250V AC(cosφ=1.0) 85℃ 
G5RL-1A-E-LN UL/C-UL Approved Models (Recognized)  SPST-NO (1a) 5~24V DC  E41643(UL508) 16A 250V AC(Resistive) 40℃
16A 24V DC(Resistive) 40℃
TV-5, 120 VAC, 40°C
VDE Approved Models SPST-NO (1a) 5、12、24V DC  40007172
(EN61810-1)
16A 250V AC(cosφ=1.0) 85℃
G5RL-K1A-EL-HA UL/C-UL Approved Models (Recognized)  SPST-NO (1a) 5~24V DC  E41643 16A 250V AC(General) - 85℃
VDE Approved Models SPST-NO (1a) 5、12、24V DC  40007172 16A 250V AC(cosφ=1.0) 85℃
IEC60669-1: 16A 250V AC Capacitor 140μF room temperature
CQC Approved Models SPST-NO (1a) 5~24V DC  CQC21002283993 16A 250V AC(cosφ=1) 85℃
G5RL-1A-TV8 UL Approved Models (Recognized)  SPST-NO (1a) 5~48V DC E41643
(UL508)
12A 277VAC General 40℃
TV-8 120VAC 40℃
A300 Pilot Duty 720VA 240VAC 40℃
1/2HP 120VAC 40℃
60LRA/10FLA 250VAC 40℃
CSA Approved Models (Certified) SPST-NO (1a) 5~48V DC LR31928 12A 277VAC General 40℃
TV-8 120VAC 40℃
A300 Pilot Duty 720VA 240VAC 40℃
1/2HP 120VAC 40℃
60LRA/10FLA 250VAC 40℃
VDE Approved Models SPST-NO (1a) 5、12、24、48V 40007172
(EN61810-1)
12A 250VAC cosφ=1 85℃
230VAC 70A(0-P) Steady 1A(rms) 85℃
G5RL-1A-E-TV8 UL Approved Models (Recognized)  SPST-NO (1a) 5~48V DC E41643
(UL508)
16A 277VAC General 40℃
TV-8 120VAC 40℃
A300 Pilot Duty 720VA 240VAC 40℃
1/2HP 120VAC 40℃
60LRA/10FLA 250VAC 40℃
CSA Approved Models (Certified) SPST-NO (1a) 5~48V DC LR31928 16A 277VAC General 40℃
TV-8 120VAC 40℃
A300 Pilot Duty 720VA 240VAC 40℃
1/2HP 120VAC 40℃
60LRA/10FLA 250VAC 40℃
VDE Approved Models SPST-NO (1a) 5、12、24、48V 40007172
(EN61810-1)
16A 250VAC cosφ=1 85℃
240VAC 100A(0-P) Steady 10A(rms) 85℃
240VAC 50A(0-P) Steady 5A(rms) 85℃
G5RL-U1A-E
G5RL-K1A-E
UL Approved Models (Recognized)  SPST-NO (1a) 5~24V DC
(“-U” models: 3~24V DC)
E41643(UL508) 16A 277V AC(Resistive) 85℃
TV-5 40℃
TV-8 40℃
8A 250V AC(Ballast) 40℃
2000W 250V AC(Tungsten) 40℃ 
CSA Approved Models (Certified) SPST-NO (1a) 5~24V DC
(“-U” models: 3~24V DC)
LR31928(CSAC22.2(No.1、No.14)) 16A 277V AC(Resistive) 85℃
TV-5 40℃
TV-8 40℃
8A 250V AC(Ballast) 40℃
2000W 250V AC(Tungsten) 40℃ 
VDE Approved Models SPST-NO (1a) 5、12、24V DC  40007172
(EN61810-1)
16A 250V AC(cosφ=1.0) 85℃
240V AC 100A(0-P) steady 10A(rms)  85℃ 
G5RL-U1-E
G5RL-K1-E
UL Approved Models (Recognized)  SPDT(1c) 5~24V DC
(“-U” models: 3~24V DC)
E41643(UL508) 16A 277V AC(Resistive) (N.O.only) 85℃
8A 250V AC(Ballast) (N.O.only) 40℃
2000W 250V AC(Tungsten) 40℃
5A 250V AC(General Use) (N.C.only)40℃  
CSA Approved Models (Certified) SPDT(1c) 5~24V DC
(“-U” models: 3~24V DC)
LR31928(CSAC22.2(No.1、No.14)) 16A 277V AC(Resistive) (N.O.only) 85℃
8A 250V AC(Ballast) (N.O.only) 40℃
2000W 250V AC(Tungsten) 40℃
5A 250V AC(General Use) (N.C.only) 40℃  
VDE Approved Models SPDT(1c) 5、12、24V DC  40007172
(EN61810-1)
16A 250V AC(cosφ=1.0) 85℃ (N.O.only)
5A 250V AC(cosφ=1.0) 85℃ (N.C.only)
G2RG-2A4 UL Approved Models (Recognized)  DPST-NO (2a) 12~24V DC  E41643(UL508) 8A 250V AC(General Use) 70℃ 
CSA Approved Models (Certified) DPST-NO (2a) 12~24V DC  LR31928(CSAC22.2
(No.0、No.14))
8A 250V AC(General Use) 70℃ 
VDE Approved Models DPST-NO (2a) 12、24V DC  40015012
(EN61810-1)
8A 250V AC(cosφ=1.0) 70℃ 
G2RG-2A-X UL Approved Models (Recognized)  DPST-NO (2a) 12、24V DC  E41643(UL508) 10 A, 500 VDC (Resistive) 85°C 
1 A, 500 VDC (Resistive) 85°C 
TÜV Approved Models DPST-NO (2a) 12、24V DC  R50468711 10 A, 500 VDC (Resistive) 85°C
1 A, 500 VDC (Resistive) 85°C
G2R( ) VDE Approved Models SPST-NO (1a)
SPDT(1c)
5、6、12、24、48、100V DC
12、24、100/110、200/220V AC
40015012
(EN61810-1)
10A 250V AC(cosφ=1.0)40℃
10A 30V DC(0ms) 40℃
16A 250V AC(cosφ=1.0)70℃
DPST-NO (2a)
DPDT (2c)
5A 250V AC(cosφ=1.0) 40℃
5A 30V DC(0ms) 40℃
TÜV Approved Models SPST-NO (1a)
SPDT(1c)
3~120V DC
6~220V AC
R50030327
(EN61810-1)
10A 250V AC(cosφ=1.0)40℃
10A 30V DC(0ms) 70℃
DPST-NO (2a)
DPDT (2c)
5A 250V AC(cosφ=1.0) 40℃
5A 30V DC(0ms) 70℃
G2R-1
G2R-14
G2R-1-H
G2R-1-T
UL Approved Models (Recognized)  SPDT(1c) 5~110V DC
12~220V AC 
E41643(UL508) 10A 30V DC(Resistive) 40℃
10A 250V AC(General Use) 40℃
5A 277V AC(General Use) 40℃
TV-3(N.O.only) 40℃ 
CSA Approved Models (Certified) SPDT(1c) 5~110V DC
12~220V AC 
LR31928(CSAC22.2
(No.0、No.14))
10A 30V DC(Resistive) 40℃
10A 250V AC(General Use) 40℃
TV-3(N.O.only) 40℃ 
G2R-1A
G2R-1A4
G2R-1A-H
G2R-1A-T
UL Approved Models (Recognized)  SPST-NO (1a) 5~110V DC
12~220V AC 
E41643(UL508) 10A 30V DC(Resistive) 40℃
10A 250V AC(General Use) 40℃
5A 277V AC(General Use) 40℃
TV-3(N.O.only) 40℃ 
CSA Approved Models (Certified) SPST-NO (1a) 5~110V DC
12~220V AC 
LR31928(CSAC22.2
(No.0、No.14))
10A 30V DC(Resistive) 40℃
10A 250V AC(General Use) 40℃
TV-3(N.O.only) 40℃ 
G2R-1-E UL Approved Models (Recognized)  SPDT(1c) 5~110V DC
12~220V AC 
E41643(UL508) 16A 30V DC(Resistive) 40℃ (N.O.only)
16A 250V AC(General Use) 40℃ (N.O.only)
TV-3(N.O.only) 40℃ 
CSA Approved Models (Certified) SPDT(1c) 5~110V DC
12~220V AC 
LR31928(CSAC22.2
(No.0、No.14))
16A 30V DC(Resistive) 40℃ (N.O.only)
16A 250V AC(General Use) 40℃ (N.O.only)
TV-3(N.O.only) 40℃ 
G2R-1A-E UL Approved Models (Recognized)  SPST-NO (1a) 5~110V DC
12~220V AC 
E41643(UL508) 16A 30V DC(Resistive) 40℃ (N.O.only)
16A 250V AC(General Use) 40℃ (N.O.only)
TV-3(N.O.only) 40℃ 
CSA Approved Models (Certified) SPST-NO (1a) 5~110V DC
12~220V AC 
LR31928(CSAC22.2
(No.0、No.14))
16A 30V DC(Resistive) 40℃ (N.O.only)
16A 250V AC(General Use) 40℃ (N.O.only)
TV-3(N.O.only) 40℃ 
G2R-2
G2R-24
G2R-2-H
UL Approved Models (Recognized)  DPDT (2c) 5~110V DC
12~220V AC 
E41643(UL508) 5A 30V DC(Resistive) 40℃
5A 250V AC(General Use) 40℃
TV-3(N.O.only) 40℃ 
CSA Approved Models (Certified) DPDT (2c) 5~110V DC
12~220V AC 
LR31928(CSAC22.2
(No.0、No.14))
5A 30V DC(Resistive) 40℃
5A 250V AC(General Use) 40℃
TV-3(N.O.only) 40℃ 
G2R-2A
G2R-2A4
G2R-2A-H
UL Approved Models (Recognized)  DPST-NO (2a) 5~110V DC
12~220V AC 
E41643(UL508) 5A 30V DC(Resistive) 40℃
5A 250V AC(General Use) 40℃
TV-3(N.O.only) 40℃ 
CSA Approved Models (Certified) DPST-NO (2a) 5~110V DC
12~220V AC 
LR31928(CSAC22.2
(No.0、No.14))
5A 30V DC(Resistive) 40℃
5A 250V AC(General Use) 40℃
TV-3(N.O.only) 40℃ 
G9KA-1A UL Approved Models (Recognized)  SPST-NO (1a) 12, 24V DC E41515 (UL508) 800V AC 50A (Resistive) at 85℃
800 V AC 50 A switch on,
200 A carry current, 50 A switch off at 85°C
TÜV Approved Models SPST-NO (1a) 12, 24V DC R50459726 800V AC 50A (Resistive) at 85℃
200 A carry current at 85°C
CQC Approved Models SPST-NO (1a) 12, 24V DC CQC20002275617 800V AC 50A (Resistive) at 85℃
200 A carry current at 85°C

| Signal Relay | Power Relay | AC Power Latching Relay | General-purpose Relay | MOS FET Relay | Solid-state Relay |
| Power MOS FET Relay | DC Power Relay | Socket |

AC Power Latching Relay

 

Model Standard Contact Operating coil ratings Standard No. Contact ratings
G9TA-U1ATH
G9TA-U1ATW
G9TA-K1ATW
G9TA-K1ATH
UL Approved Models (Recognized)  SPST-NO (1a) 12V DC  E41515 60 A, 277 V AC (Resistive) 70°C

| Signal Relay | Power Relay | AC Power Latching Relay | General-purpose Relay | MOS FET Relay | Solid-state Relay |
| Power MOS FET Relay | DC Power Relay | Socket |

General-purpose Relay

 

Model Standard Contact Operating coil ratings Standard No. Contact ratings
G7L-1A-B▢ UL Approved Models (Recognized)  SPST-NO (1a) 12~240V AC
6~220V DC 
E41643(UL508) 30A 277V AC(RES) 40℃
1.5kW 120V AC(T)40℃
1HP 120V AC 40℃
2HP 277V AC 40℃
20FLA/120LRA 120V AC 40℃
17FLA/102LRA 265V AC 40℃
TV-10 120V AC 40℃ 
CSA Approved Models (Certified) SPST-NO (1a) 12~240V AC
6~220V DC 
LR31928 30A 277V AC(RES) 40℃
2.4kW 120V AC(T)40℃
1.5HP 120V AC 40℃
3HP 277V AC 40℃
20.5FLA/105LRA 120V AC 40℃
TV-10 120V AC 40℃ 
TÜV Approved Models SPST-NO (1a) 6、12、24、48、100、110、200、220V DC
12、24、50、100~120、200~240V AC 
R50059083 30A 250V AC~(cosφ=1) 60℃
25A 250V AC~(cosφ=0.4) 60℃
30A 120V AC~(cosφ=0.4) 60℃ 
G7L-2A-B▢ UL Approved Models (Recognized)  DPST-NO (2a) 12~240V AC
6~220V DC 
E41643(UL508) 30A 277V AC(RES) 40℃
1.5kW 120V AC(T)40℃
1HP 120V AC 40℃
2HP 277V AC 40℃
20FLA/120LRA 120V AC 40℃
17FLA/102LRA 265V AC 40℃
TV-10 120V AC 40℃ 
CSA Approved Models (Certified) DPST-NO (2a) 12~240V AC
6~220V DC 
LR31928 30A 277V AC(RES) 40℃
2.4kW 120V AC(T)40℃
1.5HP 120V AC 40℃
3HP 277V AC 40℃
20.5FLA/105LRA 120V AC 40℃
TV-10 120V AC 40℃ 
TÜV Approved Models DPST-NO (2a) 6、12、24、48、100、110、200、220V DC
12、24、50、100~120、200~240V AC 
R50059083 25A 277V AC~(cosφ=0.4) 60℃ 
G7L-1A-T▢ UL Approved Models (Recognized)  SPST-NO (1a) 12~240V AC
6~220V DC 
E41643(UL508) 30A 277V AC(RES) 40℃
1.5kW 120V AC(T)40℃
1HP 120V AC 40℃
2HP 277V AC 40℃
20FLA/120LRA 120V AC 40℃
17FLA/102LRA 265V AC 40℃
TV-10 120V AC 40℃ 
CSA Approved Models (Certified) SPST-NO (1a) 12~240V AC
6~220V DC 
LR31928 30A 277V AC(RES) 40℃
2.4kW 120V AC(T)40℃
1.5HP 120V AC 40℃
3HP 277V AC 40℃
20.5FLA/105LRA 120V AC 40℃
TV-10 120V AC 40℃ 
TÜV Approved Models SPST-NO (1a) 6、12、24、48、100、110、200、220V DC
12、24、50、100~120、200~240V AC 
R50059083 25A 277V AC~(cosφ=0.4) 60℃ 
G7L-2A-T□ UL Approved Models (Recognized)  DPST-NO (2a) 12~240V AC
6~220V DC 
E41643(UL508) 30A 277V AC(RES) 40℃
1.5kW 120V AC(T) 40℃
1HP 120V AC 40℃
2HP 277V AC 40℃
20FLA/120LRA 120V AC 40℃
17FLA/102LRA 265V AC 40℃
TV-10 120V AC 40℃ 
CSA Approved Models (Certified) DPST-NO (2a) 12~240V AC
6~220V DC 
LR31928 30A 277V AC(RES) 40℃
2.4kW 120V AC(T) 40℃
1.5HP 120V AC 40℃
3HP 277V AC 40℃
20.5FLA/105LRA 120V AC 40℃
TV-10 120V AC 40℃ 
TÜV Approved Models DPST-NO (2a) 6、12、24、48、100、110、200、220V DC
12、24、50、100~120、200~240V AC 
R50059083 25A 277V AC~(cosφ=0.4) 60℃ 
G7L-1A-P UL Approved Models (Recognized)  SPST-NO (1a) 12~240V AC
6~220V DC 
E41643(UL508) 30A 277V AC(RES)40℃
1.5kW 120V AC(T) 40℃
1HP 120V AC 40℃
2HP 277V AC 40℃
20FLA/120LRA 120V AC 40℃
17FLA/102LRA 265V AC 40℃
TV-10 120V AC 40℃ 
CSA Approved Models (Certified) SPST-NO (1a) 12~240V AC
6~220V DC 
LR31928 2.4kW 120V AC(T) 40℃
1.5HP 120V AC 40℃
3HP 277V AC 40℃
20.5FLA/105LRA 120V AC 40℃
TV-10 120V AC 40℃ 
TÜV Approved Models SPST-NO (1a) 6、12、24、48、100、110、200、220V DC
12、24、50、100~120、200~240V AC 
R50059083 25A 277V AC~(cosφ=0.4) 60℃ 
G7L-2A-P UL Approved Models (Recognized)  DPST-NO (2a) 12~240V AC
6~220V DC 
E41643(UL508) 30A 277V AC(RES)40℃
1.5kW 120V AC(T) 40℃
1HP 120V AC 40℃
2HP 277V AC 40℃
20FLA/120LRA 120V AC 40℃
17FLA/102LRA 265V AC 40℃
TV-10 120V AC 40℃ 
CSA Approved Models (Certified) DPST-NO (2a) 12~240V AC
6~220V DC 
LR31928 30A 277V AC (RES) 40℃
2.4kW 120V AC(T) 40℃
1.5HP 120V AC 40℃
3HP 277V AC 40℃
20.5FLA/105LRA 120V AC 40℃
TV-10 120V AC 40℃ 
TÜV Approved Models DPST-NO (2a) 6、12、24、48、100、110、200、220V DC
12、24、50、100~120、200~240V AC 
R50059083 25A 277V AC~(cosφ=0.4) 60℃ 
G7L-2A-P-PV UL Approved Models (Recognized)  DPST-NO (2a) 12、24V DC E41643(UL508) 30A 280V AC(0.8PF) 65℃
VDE Approved Models DPST-NO (2a) 12、24V DC 1530
(EN61810-1)
30A 280V AC(cosφ=0.8) 85℃
G7L-2A-X UL/C-UL Approved Models (Recognized)  DPST-NO (2a) 12 VDC, 24 VDC E41515
(UL508)
15 A at 1000 VDC (Resistive) 85°C,
Connected in series or Break all lines
20 A at 1000 VDC (Resistive) 85°C,
Connected in series
25 A at 600 VDC (Resistive) 85°C,
Connected in series or Break all lines
VDE Approved Models DPST-NO (2a) 12 VDC, 24 VDC 40045061
(IEC61810-1)
25 A at 1000 VDC (Resistive) 85°C,
Connected in series or Break all lines
15 A at 1000 VDC (Resistive) 85°C,
Connected in series or Break all lines
25 A at 600 VDC (Resistive) 85°C,
Connected in series or Break all lines
G7L-2A-X-L UL/C-UL Approved Models (Recognized)  DPST-NO (2a) 12 VDC, 24 VDC E41515
(UL508)
15 A at 1000 VDC (Resistive) 85°C,
Connected in series or Break all lines
20 A at 1000 VDC (Resistive) 85°C,
Connected in series
20 A at 600 VDC (Resistive) 85°C,
Connected in series or Break all lines
VDE Approved Models DPST-NO (2a) 12 VDC, 24 VDC 40045061
(IEC61810-1)
20 A at 1000 VDC (Resistive) 85°C,
Connected in series or Break all lines
15 A at 1000 VDC (Resistive) 85°C,
Connected in series or Break all lines
20 A at 600 VDC (Resistive) 85°C,
Connected in series or Break all lines
G7EB-1A
G7EB-1AP1
UL Approved Models (Recognized) SPST-NO (1a) 12 VDC, 24 VDC E41515
(UL508)
800 VAC 55 A (Resistive)
800 VAC Making and Breaking 40 A,
Carrying 100 A (Resistive)
60 VDC 40 A (Resistive)
60 VDC 100 A (Resistive)
TÜV Approved Models SPST-NO (1a) 12 VDC, 24 VDC R50416743
(EN61810-1)
800 VAC, 100 A (Resistive)
60 VDC 40 A (Resistive)
60 VDC 50 A (Resistive)
60 VDC 100 A (Resistive)
CQC Approved Models SPST-NO (1a) 12 VDC, 24 VDC CQC18002207225 800 VAC, 100 A (Resistive)
60 VDC 100 A (Resistive)

| Signal Relay | Power Relay | AC Power Latching Relay | General-purpose Relay | MOS FET Relay | Solid-state Relay |
| Power MOS FET Relay | DC Power Relay | Socket |

MOS FET Relay

DIP(Dual Inline Package)

Model Standard Contact Standard No. Contact ratings
G3VM-21AR/G3VM-21DR UL Approved Models (Recognized)  SPST-NO (1a) E80555 3000mA 20V (AC peak/DC)
G3VM-21BR/G3VM-21ER UL Approved Models (Recognized)  SPST-NO (1a) E80555 4000mA 20V (AC peak/DC)
G3VM-31AR/G3VM-31DR UL Approved Models (Recognized)  SPST-NO (1a) E80555 4000mA 30V (AC peak/DC)
G3VM-31BR/G3VM-31ER UL Approved Models (Recognized)  SPST-NO (1a) E80555 5000mA 30V (AC peak/DC)
G3VM-41AY/G3VM-41DY UL Approved Models (Recognized)  SPST-NO (1a) E80555 2000mA 40V (AC peak/DC)
G3VM-41AY1/G3VM-41DY1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 2000mA 40V (AC peak/DC)
G3VM-41AR/G3VM-41DR UL Approved Models (Recognized)  SPST-NO (1a) E80555 2500mA 40V (AC peak/DC)
G3VM-41BR/G3VM-41ER UL Approved Models (Recognized)  SPST-NO (1a) E80555 3500mA 40V (AC peak/DC)
G3VM-61A1/G3VM-61D1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 500mA 60V (AC peak/DC)
G3VM-61AY/G3VM-61DY UL Approved Models (Recognized)  SPST-NO (1a) E80555 500mA 60V (AC peak/DC)
G3VM-61AY1/G3VM-61DY1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 500mA 60V (AC peak/DC)
G3VM-61AR/G3VM-61DR UL Approved Models (Recognized)  SPST-NO (1a) E80555 2000mA 60V (AC peak/DC)
G3VM-61AR1/G3VM-61DR1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 3000mA 60V (AC peak/DC)
G3VM-61B1/G3VM-61E1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 500mA 60V (AC peak/DC)
G3VM-61BR/G3VM-61ER UL Approved Models (Recognized)  SPST-NO (1a) E80555 2500mA 60V (AC peak/DC)
G3VM-61BR1/G3VM-61ER1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 3000mA 60V (AC peak/DC)
G3VM-61BR2/G3VM-61ER2 UL Approved Models (Recognized)  SPST-NO (1a) E80555 4000mA 60V (AC peak/DC)
G3VM-61CR1/G3VM-61FR1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 5000mA 60V (AC peak/DC)
G3VM-62C1/G3VM-62F1 UL Approved Models (Recognized)  DPST-NO (2a) E80555 500mA 60V (AC peak/DC)
G3VM-101AR/G3VM-101DR UL Approved Models (Recognized)  SPST-NO (1a) E80555 1000mA 100V (AC peak/DC)
G3VM-101AR1/G3VM-101DR1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 2000mA 100V (AC peak/DC)
G3VM-101BR/G3VM-101ER UL Approved Models (Recognized)  SPST-NO (1a) E80555 2000mA 100V (AC peak/DC)
G3VM-101BR1/G3VM-101ER1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 3500mA 100V (AC peak/DC)
G3VM-101CR/G3VM-101FR UL Approved Models (Recognized)  SPST-NO (1a) E80555 3000mA 100V (AC peak/DC)
G3VM-201AY/G3VM-201DY UL Approved Models (Recognized)  SPST-NO (1a) E80555 250mA 200V (AC peak/DC)
G3VM-201AR/G3VM-201DR UL Approved Models (Recognized)  SPST-NO (1a) E80555 700mA 200V (AC peak/DC)
G3VM-201CR/G3VM-201FR UL Approved Models (Recognized)  SPST-NO (1a) E80555 1500mA 200V (AC peak/DC)
G3VM-201AY1/G3VM-201DY1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 250mA 200V (AC peak/DC)
G3VM-351AY/G3VM-351DY UL Approved Models (Recognized)  SPST-NO (1a) E80555 100mA 350V (AC peak/DC)
G3VM-351AY1/G3VM-351DY1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 100mA 350V (AC peak/DC)
G3VM-2L/G3VM-2FL UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 350V (AC peak/DC)
G3VM-351A/G3VM-351D UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 350V (AC peak/DC)
EN60950/60065 Approved Models
(SEMKO Approved) (Certified)
SPST-NO (1a) 8816, 8817 ――
G3VM-353A/G3VM-353D UL Approved Models (Recognized)  SPST-NC (1b) E80555 150mA 350V (AC peak/DC)
G3VM-351B/G3VM-351E UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 350V (AC peak/DC)
G3VM-353B/G3VM-353E UL Approved Models (Recognized)  SPST-NC (1b) E80555 150mA 350V (AC peak/DC)
G3VM-352C/G3VM-352F UL Approved Models (Recognized)  DPST-NO (2a) E80555 120mA 350V (AC peak/DC)
EN60950/60065 Approved Models
(SEMKO Approved) (Certified)
DPST-NO (2a) 8816, 8817 ――
G3VM-WL/G3VM-WFL UL Approved Models (Recognized)  DPST-NO (2a) E80555 120mA 350V (AC peak/DC)
G3VM-354C/G3VM-354F UL Approved Models (Recognized)  DPST-NC (2b) E80555 150mA 350V (AC peak/DC)
G3VM-401A/G3VM-401D UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 400V (AC peak/DC)
G3VM-401AY/G3VM-401DY UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 400V (AC peak/DC)
G3VM-401AY1/G3VM-401DY1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 400V (AC peak/DC)
G3VM-401B/G3VM-401E UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 400V (AC peak/DC)
G3VM-401BY/G3VM-401EY UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 400V (AC peak/DC)
G3VM-401CR/G3VM-401FR UL Approved Models (Recognized)  SPST-NO (1a) E80555 400mA 400V (AC peak/DC)
G3VM-402C/G3VM-402F UL Approved Models (Recognized)  DPST-NO (2a) E80555 120mA 400V (AC peak/DC)
G3VM-601AY/G3VM-601DY UL Approved Models (Recognized)  SPST-NO (1a) E80555 90mA 600V (AC peak/DC)
G3VM-601AY1/G3VM-601DY1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 90mA 600V (AC peak/DC)
G3VM-601BY/G3VM-601EY UL Approved Models (Recognized)  SPST-NO (1a) E80555 100mA 600V (AC peak/DC)
G3VM-601CR/G3VM-601FR UL Approved Models (Recognized)  SPST-NO (1a) E80555 600mA 600V (AC peak/DC)

SOP(Small Outline Package)

Model Standard Contact Standard No. Contact ratings
G3VM-21GR UL Approved Models (Recognized)  SPST-NO (1a) E80555 160mA 20V (AC peak/DC)
G3VM-21GR1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 300mA 20V (AC peak/DC)
G3VM-21HR UL Approved Models (Recognized)  SPST-NO (1a) E80555 2500mA 20V (AC peak/DC)
G3VM-31HR UL Approved Models (Recognized)  SPST-NO (1a) E80555 4000mA 30V (AC peak/DC)
G3VM-41GR6 UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 40V (AC peak/DC)
G3VM-41GR4 UL Approved Models (Recognized)  SPST-NO (1a) E80555 250mA 40V (AC peak/DC)
G3VM-41GR5 UL Approved Models (Recognized)  SPST-NO (1a) E80555 300mA 40V (AC peak/DC)
G3VM-41GR8 UL Approved Models (Recognized)  SPST-NO (1a) E80555 1000mA 40V (AC peak/DC)
G3VM-41HR UL Approved Models (Recognized)  SPST-NO (1a) E80555 2500mA 40V (AC peak/DC)
G3VM-61VY1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 100mA 60V (AC peak/DC)
G3VM-61VY2 UL Approved Models (Recognized)  SPST-NO (1a) E80555 500mA 60V (AC peak/DC)
G3VM-61VY3 UL Approved Models (Recognized)  SPST-NO (1a) E80555 700mA 60V (AC peak/DC)
G3VM-61G2 UL Approved Models (Recognized)  SPST-NO (1a) E80555 400mA 60V (AC peak/DC)
G3VM-61G3 UL Approved Models (Recognized)  SPST-NO (1a) E80555 400mA 60V (AC peak/DC)
G3VM-61GR2 UL Approved Models (Recognized)  SPST-NO (1a) E80555 1700mA 60V (AC peak/DC)
G3VM-61VR UL Approved Models (Recognized)  SPST-NO (1a) E80555 1400mA 60V (AC peak/DC)
G3VM-63G UL Approved Models (Recognized)  SPST-NC (1b) E80555 500mA 60V (AC peak/DC)
G3VM-61H1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 400mA 60V (AC peak/DC)
G3VM-61HR UL Approved Models (Recognized)  SPST-NO (1a) E80555 2300mA 60V (AC peak/DC)
G3VM-61HR1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 3300mA 60V (AC peak/DC)
G3VM-62J1 UL Approved Models (Recognized)  DPST-NO (2a) E80555 400mA 60V (AC peak/DC)
G3VM-81GR UL Approved Models (Recognized)  SPST-NO (1a) E80555 40mA 80V (AC peak/DC)
G3VM-81GR1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 200mA 80V (AC peak/DC)
G3VM-81G1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 350mA 80V (AC peak/DC)
G3VM-81HR UL Approved Models (Recognized)  SPST-NO (1a) E80555 1250mA 80V (AC peak/DC)
G3VM-101HR UL Approved Models (Recognized)  SPST-NO (1a) E80555 1400mA 100V (AC peak/DC)
G3VM-101HR1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 2000mA 100V (AC peak/DC)
G3VM-201G UL Approved Models (Recognized)  SPST-NO (1a) E80555 50mA 200V (AC peak/DC)
G3VM-201G1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 200mA 200V (AC peak/DC)
G3VM-201G2 UL Approved Models (Recognized)  SPST-NO (1a) E80555 200mA 200V (AC peak/DC)
G3VM-S5 UL Approved Models (Recognized)  SPST-NO (1a) E80555 200mA 200V (AC peak/DC)
G3VM-201H1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 200mA 200V (AC peak/DC)
G3VM-202J1 UL Approved Models (Recognized)  DPST-NO (2a) E80555 200mA 200V (AC peak/DC)
G3VM-351G1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 100mA 350V (AC peak/DC)
G3VM-351VY UL Approved Models (Recognized)  SPST-NO (1a) E80555 110mA 350V (AC peak/DC)
G3VM-353G UL Approved Models (Recognized)  SPST-NC (1b) E80555 120mA 350V (AC peak/DC)
G3VM-351H UL Approved Models (Recognized)  SPST-NO (1a) E80555 110mA 350V (AC peak/DC)
G3VM-353H UL Approved Models (Recognized)  SPST-NC (1b) E80555 120mA 350V (AC peak/DC)
G3VM-355JR UL Approved Models (Recognized)  SPST-NO (1a)+SPST-NC (1b) E80555 120mA 350V (AC peak/DC)
G3VM-352J UL Approved Models (Recognized)  DPST-NO (2a) E80555 110mA 350V (AC peak/DC)
G3VM-354J UL Approved Models (Recognized)  DPST-NC (2b) E80555 120mA 350V (AC peak/DC)
G3VM-31HR1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 4500mA 30V (AC peak/DC)
G3VM-61HR2 UL Approved Models (Recognized)  SPST-NO (1a) E80555 4000mA 60V (AC peak/DC)
G3VM-101HR2 UL Approved Models (Recognized)  SPST-NO (1a) E80555 3000mA 100V (AC peak/DC)
G3VM-401G1 UL certification pending. SPST-NO (1a) E80555 100mA 400V (AC peak/DC)
G3VM-401G UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 400V (AC peak/DC)
EN60950/60065 Approved Models
(SEMKO Approved) (Certified)
SPST-NO (1a) 8884, 8885 ――
G3VM-401H UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 400V (AC peak/DC)
EN60950/60065 Approved Models
(SEMKO Approved) (Certified)
SPST-NO (1a) 8884, 8885 ――
G3VM-402J UL Approved Models (Recognized)  DPST-NO (2a) E80555 120mA 400V (AC peak/DC)
EN60950/60065 Approved Models
(SEMKO Approved) (Certified)
DPST-NO (2a) 8884, 8885 ――
G3VM-601G1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 70mA 600V (AC peak/DC)
G3VM-601G UL Approved Models (Recognized)  SPST-NO (1a) E80555 90mA 600V (AC peak/DC)

SSOP(Shrink Small Outline Package)

Model Standard Contact Standard No. Contact ratings
G3VM-21LR UL Approved Models (Recognized)  SPST-NO (1a) E80555 160mA 20V (AC peak/DC)
G3VM-21LR10 UL Approved Models (Recognized)  SPST-NO (1a) E80555 200mA 20V (AC peak/DC)
G3VM-21LR1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 450mA 20V (AC peak/DC)
G3VM-21LR11 UL Approved Models (Recognized)  SPST-NO (1a) E80555 900mA 20V (AC peak/DC)
G3VM-41LR10 UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 40V (AC peak/DC)
G3VM-41LR6 UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 40V (AC peak/DC)
G3VM-41LR11 UL Approved Models (Recognized)  SPST-NO (1a) E80555 140mA 40V (AC peak/DC)
G3VM-41LR4 UL Approved Models (Recognized)  SPST-NO (1a) E80555 250mA 40V (AC peak/DC)
G3VM-41LR5 UL Approved Models (Recognized)  SPST-NO (1a) E80555 300mA 40V (AC peak/DC)
G3VM-61LR UL Approved Models (Recognized)  SPST-NO (1a) E80555 400mA 60V (AC peak/DC)
G3VM-81LR UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 80V (AC peak/DC)
G3VM-101LR UL Approved Models (Recognized)  SPST-NO (1a) E80555 80mA 100V (AC peak/DC)

USOP(Ultra Small Outline Package)

Model Standard Contact Standard No. Contact ratings
G3VM-21PR10 UL Approved Models (Recognized)  SPST-NO (1a) E80555 200mA 20V (AC peak/DC)
G3VM-21PR1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 450mA 20V (AC peak/DC)
G3VM-21PR11 UL Approved Models (Recognized)  SPST-NO (1a) E80555 900mA 20V (AC peak/DC)
G3VM-41PR12 UL Approved Models (Recognized)  SPST-NO (1a) E80555 100mA 40V (AC peak/DC)
G3VM-41PR10 UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 40V (AC peak/DC)
G3VM-41PR6 UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 40V (AC peak/DC)
G3VM-41PR11 UL Approved Models (Recognized)  SPST-NO (1a) E80555 140mA 40V (AC peak/DC)
G3VM-41PR5 UL Approved Models (Recognized)  SPST-NO (1a) E80555 300mA 40V (AC peak/DC)
G3VM-51PR UL Approved Models (Recognized)  SPST-NO (1a) E80555 300mA 50V (AC peak/DC)
G3VM-61PR1 UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 60V (AC peak/DC)
G3VM-61PR UL Approved Models (Recognized)  SPST-NO (1a) E80555 400mA 60V (AC peak/DC)
G3VM-71PR UL Approved Models (Recognized)  SPST-NO (1a) E80555 400mA 75V (AC peak/DC)
G3VM-81PR UL Approved Models (Recognized)  SPST-NO (1a) E80555 120mA 80V (AC peak/DC)
G3VM-101PR UL Approved Models (Recognized)  SPST-NO (1a) E80555 100mA 100V (AC peak/DC)

| Signal Relay | Power Relay | AC Power Latching Relay | General-purpose Relay | MOS FET Relay | Solid-state Relay |
| Power MOS FET Relay | DC Power Relay | Socket |

Solid-state Relay

 

Model Standard Standard No. Contact ratings
G3CN-202P(L)(1)-US UL Approved Models (Recognized)  E64562(UL508) 2A 264V AC (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 2A 264V AC (Resistive) 40℃
G3CN-203P(L)(1)-US UL Approved Models (Recognized)  E64562(UL508) 3A 264V AC (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 3A 264V AC (Resistive) 40℃
G3CN-DX02P(1)-US UL Approved Models (Recognized)  E64562(UL508) 2A 52.8V DC (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 2A 52.8V DC (Resistive) 40℃
G3CN-DX03P(1)-US UL Approved Models (Recognized)  E64562(UL508) 3A 52.8V DC (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 3A 52.8V DC (Resistive) 40℃
G3M-203P(L)-UTU(-1)(-4) UL Approved Models (Recognized)  E64562(UL508) 3A 250V AC (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 3A 250V AC (Resistive) 40℃
TÜV Approved Models J50063395(EN60950-1) 3A 250V AC 40℃
G3M-203P(L)(-4) UL Approved Models (Recognized)  E64562(UL508) 3A 250V AC  (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 3A 250V AC  (Resistive) 40℃
G3M-205P(L)-VD(-1)(-4) UL Approved Models (Recognized)  E64562(UL508) 5A 250V AC  (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 5A 250V AC  40℃
VDE Approved Models 10148(EN60950-1(VDE0805)) 5A 100-240V AC 80℃
G3S-201PL-US UL Approved Models (Recognized)  E64562(UL508) 1A 250V AC  (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 1A 250V AC  (Resistive) 40℃
G3S-201PL-PD-US UL Approved Models (Recognized)  E64562(UL508) 1.2A 250V AC  (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 1.2A 250V AC  (Resistive) 40℃
G3SD-Z01P-US UL Approved Models (Recognized)  E64562(UL508) 1A 24V DC  (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 1A 24V DC  (Resistive) 40℃
G3SD-Z01P-PD-US UL Approved Models (Recognized)  E64562(UL508) 1.1A 24V DC  (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 1.0A 24V DC (Resistive) 40℃
G3TB-IAZR02P-US UL Approved Models (Recognized)  E41515(UL508) 25mA 24V DC (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 25mA 24V DC (Resistive) 40℃
G3TB-IDZR02P-US UL Approved Models (Recognized)  E41515(UL508) 25mA 24V DC (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 25mA 24V DC (Resistive) 40℃
G3TB-OA203PZ(M)-US UL Approved Models (Recognized)  E41515(UL508) 3A 240V AC (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 3A 240V AC (Resistive) 40℃
G3TB-OA203PL(M)-US UL Approved Models (Recognized)  E41515(UL508) 3A 240V AC (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 3A 240V AC (Resistive) 40℃
G3TB-ODX03P(M)-US UL Approved Models (Recognized)  E41515(UL508) 3A 48V DC (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 3A 48V DC (Resistive) 40℃
G3TB-OD201P(M)-US UL Approved Models (Recognized)  E41515(UL508) 1.5A 200V DC (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 1.5A 200V DC (Resistive) 40℃
G3R-IAZR1SN-UTU UL Approved Models (Recognized) E64562(UL508) 100mA 32V DC (General purpose) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 100mA 32V DC (General purpose) 40℃
TÜV Approved Models J50064704(EN60950-1) 100mA 32V DC 40℃
G3R-IDZR1SN-UTU UL Approved Models (Recognized)  E64562(UL508) 100mA 32V DC (General purpose) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 100mA 32V DC (General purpose) 40℃
TÜV Approved Models J50064704(EN60950-1) 100mA 32V DC 40℃
G3R-IDZR1SN-1-UTU UL Approved Models (Recognized)  E64562(UL508) 100mA 32V DC (General purpose) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 100mA 32V DC (General purpose) 40℃
TÜV Approved Models J50064704(EN60950-1) 100mA 32V DC 40℃
G3R-OA202SZN-UTU UL Approved Models (Recognized)  E64562(UL508) 2A 264V AC (General purpose) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 2A 264V AC (General purpose) 40℃
TÜV Approved Models J50064704(EN60950-1) 2A 240V AC 40℃
G3R-102P(L)N-US UL Approved Models (Recognized)  E64562(UL508) 2A 125V AC (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14) 2A 125V AC (Resistive) 40℃
G3R-202P(L)N-US UL Approved Models (Recognized)  E64562(UL508) 2A 250V AC (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14) 2A 250V AC (Resistive) 40℃
G3RD-X02PN-US UL Approved Models (Recognized)  E64562(UL508) 2A 50V DC (Resistive) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14) 2A 50V DC (Resistive) 40℃
G3R-OA202SLN-UTU UL Approved Models (Recognized)  E64562(UL508) 2A 264V AC (General purpose) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 2A 264V AC (General purpose) 40℃
TÜV Approved Models J50064704(EN60950-1) 2A 240V AC 40℃
G3R-ODX02SN-UTU UL Approved Models (Recognized)  E64562(UL508) 2A 60V DC (General purpose) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 2A 60V DC (General purpose) 40℃
TÜV Approved Models J50064704(EN60950-1) 2A 60V DC 40℃
G3R-OD201SN-UTU UL Approved Models (Recognized)  E64562(UL508) 1.5A 200V DC (General purpose) 40℃
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 1.5A 200V DC (General purpose) 40℃
TÜV Approved Models J50064704(EN60950-1) 1.5A 200V DC 40℃

| Signal Relay | Power Relay | AC Power Latching Relay | General-purpose Relay | MOS FET Relay | Solid-state Relay |
| Power MOS FET Relay | DC Power Relay | Socket |

Power MOS FET Relay

 

Model Standard Standard No. Contact ratings
G3DZ-2R6PL UL Approved Models (Recognized) E64562(UL508) 0.6A 240V AC
0.6A 125V DC
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 0.6A 240V AC
0.6A 125V DC
G3DZ-1R5PL UL Approved Models (Recognized) E64562(UL508) 0.5A 100AC
0.6A 100VDC
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 0.5A 100AC
0.6A 100VDC
G3DZ-DZ02P UL Approved Models (Recognized) E64562(UL508) 2A 24VDC
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 2A 24VDC
G3DZ-1R5PLG UL Approved Models (Recognized) E64562(UL508) 0.5A 125AC
0.6A 100VDC
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 0.5A 125AC
0.6A 100VDC
G3DZ-DZ02PG UL Approved Models (Recognized) E64562(UL508) 2A 26.4VDC
CSA Approved Models (Certified) LR35535(CSAC22.2(No.14)) 2A 26.4VDC

| Signal Relay | Power Relay | AC Power Latching Relay | General-purpose Relay | MOS FET Relay | Solid-state Relay |
| Power MOS FET Relay | DC Power Relay | Socket |

DC Power Relay

 

Model Standard Contact Operating coil ratings Standard No. Contact ratings
G9EA UL/C-UL (CSA) Approved Models (Recognized) 1a  12~110V DC  E41515(UL508)(C22.2No.14) 60A 277V AC(Resistive)
60A 400V DC(Resistive) 
G9EA(CA) UL/C-UL (CSA) Approved Models (Recognized) 1a  12~110V DC  E41515(UL508)(C22.2No.14) 30A 277V AC(Resistive)
30A 400V DC(Resistive)
100A 120V DC(Resistive) 
G9EC UL/C-UL (CSA) Approved Models (Recognized) 1a  12~100V DC  E41515(UL508)(C22.2No.14) 200A 400V DC  
200A 277V AC  
G9EC(AQ) UL/C-UL (CSA) Approved Models (Recognized) 1a 12~24V DC E41515(UL508)(C22.2No.14) 150A 400V DC(Resistive)
G9EN-1-UVD UL/C-UL (CSA) Approved Models (Recognized) 1a 12~24V DC E41515(UL508)(C22.2No.14) 60A 277V AC(Resistive)
60A 500V DC(Resistive) 
G9EJ-1-(P)-E-UVD UL/C-UL (CSA) Approved Models (Recognized) 1a 12~24V DC E41515(UL508)(C22.2No.14) 15A 500V DC(Resistive) 

| Signal Relay | Power Relay | AC Power Latching Relay | General-purpose Relay | MOS FET Relay | Solid-state Relay |
| Power MOS FET Relay | DC Power Relay | Socket |

Socket

 

Model Standard Standard No. Contact ratings
P6B-06 UL/C-UL (CSA) Approved Models (Recognized) E87929 5A 250V AC
CSA Approved Models (Certified) 5A 250V AC
P6B-26P UL/C-UL (CSA) Approved Models (Recognized) E87929 5A 250V AC
CSA Approved Models (Certified) LR31928 5A 250V AC
P6C UL/C-UL (CSA) Approved Models (Recognized) E87929 10A 250V AC
CSA Approved Models (Certified) LR31928 10A 250V AC
P6D-04P UL/C-UL (CSA) Approved Models (Recognized) E87929 5A 250V AC
CSA Approved Models (Certified) LR31928 5A 250V AC
P7SA-□ UL Approved Models (Recognized) E87929 ――
CSA Approved Models (Certified) LR35535 ――
VDE Approved Models No.40007586(EN61984) ――
P7S-□ UL Approved Models (Recognized) E87929 ――
CSA Approved Models (Certified) LR35535 ――
VDE Approved Models No.40007595(IEC61984) ――

| Micro Switch | Rocker Switch | Pushbutton Switch |

Micro Switch

 

Model Standards Standard No. Rating
V-21 UL Approved Models (Recognized)  E41515(UL1054) 21A 125V、21A 250V AC(General Use)
0.6A 125 V、0.3A 250V DC(Resistive)
1/2HP 125V、1/2HP 250V AC (Rated horsepower)
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 21A 125V、21A 250V AC(General Use)
0.6A 125 V、0.3A 250V DC(Resistive)
1/2HP 125V、1/2HP 250V AC (Rated horsepower)
VDE Approved Models 40025231(EN61058-1) 20(4)A 250VAC(Resistive and Motor) 50,000 operation with rated load
V-16 UL Approved Models (Recognized)  E41515(UL1054) 16A 125V、16A 250V AC(General Use)
0.6A 125 V、0.3A 250V DC(Resistive)
1/2HP 125V、1/2HP 250V AC (Rated horsepower)
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 16A 125V、16A 250V AC(General Use)
0.6A 125 V、0.3A 250V DC(Resistive)
1/2HP 125V、1/2HP 250V AC (Rated horsepower)
VDE Approved Models 40025231(EN61058-1) 16(3)A 250VAC(Resistive and Motor) 50,000 operation with rated load
V-15 UL Approved Models (Recognized)  E41515(UL1054) 15A 125V、15A 250V AC(General Use)
0.6A 125 V、0.3A 250V DC(Resistive)
1/2HP 125V、1/2HP 250V AC (Rated horsepower)
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 15A 125V、15A 250V AC(General Use)
0.6A 125 V、0.3A 250V DC(Resistive)
1/2HP 125V、1/2HP 250V AC (Rated horsepower)
V-11 UL Approved Models (Recognized)  E41515(UL1054) 11A 125V、11A 250V AC(General Use)
0.6A 125 V、0.3A 250V DC(Resistive)
1/2HP 125V、1/2HP 250V AC (Rated horsepower)
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 11A 125V、11A 250V AC(General Use)
0.6A 125 V、0.3A 250V DC(Resistive)
1/2HP 125V、1/2HP 250V AC (Rated horsepower)
VDE Approved Models 40025231(EN61058-1) 11(2)A 250VAC(Resistive and Motor)50,000 operation with rated load
V-10 UL Approved Models (Recognized)  E41515(UL1054) 10A 125V、10A 250V AC(General Use)
0.6A 125 V、0.3A 250V DC(Resistive)
1/2HP 125V、1/2HP 250V AC (Rated horsepower)
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 10A 125V、10A 250V AC(General Use)
0.6A 125 V、0.3A 250V DC(Resistive)
1/2HP 125V、1/2HP 250V AC (Rated horsepower)
D3V-01 UL/C-UL (CSA) Approved Models (Recognized) E41515(UL61058-1/CSAC22.2No.61058-1) 0.1A 125V AC(General Use)
0.1A 30V DC(Resistive) 
VDE Approved Models 40024894(EN61058-1) 0.1A 125V AC (Resistive) 50,000 operation with rated load
VX-5 UL/C-UL (CSA) Approved Models (Recognized) E41515(UL61058-1/CSAC22.2No.61058-1) 5A 125V AC、5A 250V AC(General Use) 
VDE Approved Models 124761(EN61058-1) 5A 250V AC (Resistive) 50,000 operation with rated load
5A 125V AC (Resistive) 50,000 operation with rated load
VX-01 UL/C-UL (CSA) Approved Models (Recognized) E41515(UL61058-1/CSAC22.2No.61058-1) 0.1A 125V AC(General Use)
0.1A 30V DC(Resistive) 
VDE Approved Models 124761(EN61058-1) 0.1A 125V AC (Resistive) 50,000 operation with rated load
D2MV-1 UL Approved Models (Recognized)  E41515(UL1054) 1A 125V AC(General Use)
1A 30V DC(Resistive) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 1A 125V AC(General Use)
1A 30V DC(Resistive) 
D2MV-01 UL Approved Models (Recognized)  E41515(UL1054) 0.1A 125V AC(General Use)
0.1A 30V DC(Resistive) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 0.1A 125V AC(General Use)
0.1A 30V DC(Resistive) 
D2MC-5 UL Approved Models (Recognized)  E41515(UL1054) 5A 125 V、5A 250V AC(General Use) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 5A 125 V、5A 250V AC(General Use) 
D2MC-01 UL Approved Models (Recognized)  E41515(UL1054) 0.5A 125V AC(General Use)
0.5A 30V DC(Resistive) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 0.5A 125V AC(General Use)
0.5A 30V DC(Resistive) 
D3M UL/C-UL (CSA) Approved Models (Recognized) E41515(UL61058-1/CSAC22.2No.61058-1) 0.1A 30V DC(Resistive) 
TÜV Approved Models R9750979(EN61058-1) 0.1A 30V DC (Resistive) 100,000 operation with rated load
SS-10 UL Approved Models (Recognized)  E41515(UL1054) 10.1A 250V AC(General Use) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 10.1A 250V AC(General Use) 
TÜV Approved Models 125256(EN61058-1) 10A 250V AC (Resistive) 50,000 operation with rated load
SS-5 UL Approved Models (Recognized)  E41515(UL1054) 5A 125V、3A 250V AC(General Use) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 5A 125V、3A 250V AC(General Use) 
TÜV Approved Models 129246(EN61058-1) 5A 250V AC (Resistive) 50,000 operation with rated load
SS-01 UL Approved Models (Recognized)  E41515(UL1054) 0.1A 125V AC(General Use)
0.1A 30V DC(Resistive) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 0.1A 125V AC(General Use)
0.1A 30V DC(Resistive) 
SS-3P UL/C-UL (CSA) Approved Models (Recognized) E41515(UL1054)(CSAC22.2No.55) 3A 125V AC(Resistive)
3A 30V DC(Resistive) 
VDE Approved Models 40008425(EN61058-1) 3A 125V AC (Resistive) 50,000 operation with rated load
3A 30V DC (Resistive) 50,000 operation with rated load
SS-01P UL/C-UL (CSA) Approved Models (Recognized) E41515(UL1054)(CSAC22.2No.55) 0.1A 125V AC(Resistive)
0.1A 30V DC(Resistive) 
VDE Approved Models 40008425(EN61058-1) 0.1A 125V AC (Resistive) 50,000 operation with rated load
0.1A 30V DC (Resistive) 50,000 operation with rated load
D2S-10 UL Approved Models (Recognized)  E41515(UL1054) 10.1A 250V AC(General Use) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 10.1A 250V AC(General Use) 
D2S-5 UL Approved Models (Recognized)  E41515(UL1054) 5A 125V AC、3A 250V AC(General Use) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 5A 125V AC、3A 250V AC(General Use) 
D2S-01 UL Approved Models (Recognized)  E41515(UL1054) 0.1A 125V AC(General Use)
0.1A 30V DC(Resistive) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 0.1A 125V AC(General Use)
0.1A 30V DC(Resistive) 
D2F UL Approved Models (Recognized)  E41515(UL1054) 3A 125V AC(General Use)
2A 30V DC(Resistive) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 3A 125V AC(General Use)
2A 30V DC(Resistive) 
D2F-F UL Approved Models (Recognized)  E41515(UL1054) 1A 125V AC(General Use)
0.5A 30V DC(Resistive) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 1A 125V AC(General Use)
0.5A 30V DC(Resistive) 
D2F-01 UL Approved Models (Recognized)  E41515(UL1054) 0.1A 30V DC(Resistive) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 0.1A 30V DC(Resistive) 
J-7 UL Approved Models (Recognized)  E41515(UL508) 7A 125V、7A 250V AC(General Use) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 7A 125V、7A 250V AC(General Use) 
D2VW-5 UL Approved Models (Recognized)  E41515(UL61058-1)(CSAC22.2No.61058-1) 3A 125、250V AC(General Use) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 3A 125、250V AC(General Use) 
VDE Approved Models 104068(EN61058-1) 3A 250V AC (Resistive) 25,000 operation with rated load
D2VW-01 UL Approved Models (Recognized)  E41515(UL61058-1)(CSAC22.2No.61058-1) 0.1A 125V AC(General Use)
0.1A 30V DC(Resistive) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 0.1A 125V AC(General Use)
0.1A 30V DC(Resistive) 
VDE Approved Models 104068(EN61058-1) 0.1A 125V AC (Resistive) 100,000 operation with rated load
D2SW-3 UL Approved Models (Recognized)  E41515(UL61058-1)(CSAC22.2No.61058-1) 3A 125V AC、2A 250V AC(General Use)
3A 30V DC(Resistive) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 3A 125V AC、2A 250V AC(General Use)
3A 30V DC(Resistive) 
VDE Approved Models 85002(EN61508-1) 2A 250V AC (Resistive) 30,000 operation with rated load
2A 30V DC (Resistive) 30,000 operation with rated load
D2SW-01 UL Approved Models (Recognized)  E41515(UL61058-1)(CSAC22.2No.61058-1) 0.1A 125V AC(General Use)
0.1A 30V DC(Resistive) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 0.1A 125V AC(General Use)
0.1A 30V DC(Resistive) 
VDE Approved Models 85002(EN61058-1) 0.1A 125V AC (Resistive) 50,000 operation with rated load
0.1A 30V DC (Resistive) 50,000 operation with rated load
D2SW-P2 UL/C-UL (CSA) Approved Models (Recognized) E41515(UL1054)(CSAC22.2No.55) 2A 250V AC(General Use) 2A 30V DC(Resistive) 
VDE Approved Models 40011840(EN61058-1) 2A 250V AC (Resistive) 50,000 operation with rated load
2A 30V DC (Resistive) 50,000 operation with rated load
D2SW-P01 UL/C-UL (CSA) Approved Models (Recognized) E41515(UL1054)(CSAC22.2No.55) 0.1A 125V AC(General Use)
0.1A 30V DC(Resistive) 
VDE Approved Models 40011840(EN61058-1) 0.1A 125V AC (Resistive) 50,000 operation with rated load
0.1A 30V DC (Resistive) 50,000 operation with rated load
D2HW UL/C-UL (CSA) Approved Models (Recognized) E41515(UL61058-1)(CSAC22.2No.61058-1) 0.1A 100V AC(Resistive)
2A 12V DC(Resistive)
1A 24V DC(Resistive)
0.5A 42V DC(Resistive)
D3D UL/C-UL (CSA) Approved Models (Recognized) E41515(UL61058-1/CSAC22.2No.61058-1) 0.5A 250V AC(Resistive)
1A 125V AC(Resistive) 
VDE Approved Models 40005053(EN61058-1) 0.5A 250V AC (Resistive) 50,000 operation with rated load
1A 125V AC (Resistive) 50,000 operation with rated load
D3DC UL/C-UL (CSA) Approved Models (Recognized) E41515(UL61058-1/CSAC22.2No.61058-1) 0.1A 30V DC(Resistive) 
D2D-1 UL/C-UL (CSA) Approved Models (Recognized)  E41515(UL61058-1/CSAC22.2No.61058-1) 16A 250V AC(General Use) 
VDE Approved Models 136005(EN61058-1) 16(4)A 250V AC(Resistive and Motor) 10,000 operation with rated load
D2D-2 UL/C-UL (CSA) Approved Models (Recognized)  E41515(UL61058-1/CSAC22.2No.61058-1) 10A 250V AC(General Use) 
VDE Approved Models 136005(EN61058-1) 10A 250V AC (Resistive) 10,000 operation with rated load
D2D-3 UL/C-UL (CSA) Approved Models (Recognized)  E41515(UL61058-1/CSAC22.2No.61058-1) 16A 250V AC(General Use)
3/4HP 125V, 1-1/2HP 250V AC (Rated horsepower)
VDE Approved Models 136005(EN61058-1) 16(4)A 250VAC(Resistive and Motor) 10,000 operation with rated load
D2T UL/C-UL (CSA) Approved Models (Recognized)  E41515(UL61058-1/CSAC22.2No.61058-1) 5A 125V AC、5A 250V AC Terminal 1-2 (General Use)
0.1A 125V AC Terminal 3-4 (General Use) 
VDE Approved Models 120144(EN61058-1) 5A 250V AC (Terminal 1-2) 50,000 operation with rated load(Resistive)
0.1A 125V AC (Terminal 3-4) 50,000 operation with rated load(Resistive) 
C4V UL/C-UL (CSA) Approved Models (Recognized) E41515(UL1054)(CSAC22.2No.55) 8A 250V AC (General Use) 
TÜV Approved Models R 50175655(EN61058-1) 8A 250V AC (Resistive) 10,000 operation with rated load

| Micro Switch | Rocker Switch | Pushbutton Switch |

Rocker Switch

 

Model
Standards
Standard No. Rating
A8G UL/C-UL (CSA) Approved Models (Recognized) E41515(UL1054/CSAC22.2No.55) 20A 250V AC(General Use) 
KEMA Approved Models 2138567.01(EN61058-1) 20(8)A 250VAC(Resistive and Motor)
A8A UL Approved Models (Recognized)  E41515(UL508) 16A 125V AC(General Use)
16A 250V AC(General Use) 
CSA Approved Models (Certified) LR21642(CSAC22.2No.55) 16A 125V AC(General Use)
16A 250V AC(General Use) 
VDE Approved Models 40000785(EN61058-1) 16A 250V AC(Resistive) 
A8L UL/C-UL (CSA) Approved Models (Recognized) E41515(UL1054/CSAC22.2No.55) 10A 125V AC(General Use)
10A 250V AC(General Use) 
TÜV Approved Models R50175687(EN61058-1) 10(8)A 250VAC(Resistive and Motor)
A8M UL/C-UL (CSA) Approved Models (Recognized) E41515(UL1054/CSAC22.2No.55) 16A 125V AC(General Use)
16A 250V AC(General Use) 
VDE Approved Models 40026936(EN61058-1) 16A 125V AC(Resistive)
16A 250V AC(Resistive) 
A8W UL/C-UL (CSA) Approved Models (Recognized) E41515(UL1054/CSAC22.2No.55) 16A 125V AC(General Use)
16A 250V AC(General Use)
TV-8 
DEMKO Approved Models 152835-05(EN61058-1) 16A 125V AC(Resistive)
16A 250V AC(Resistive) 
A8N UL/C-UL (CSA) Approved Models (Recognized) E41515(UL1054/CSAC22.2No.55) 16A 125V AC(General Use)
16A 250V AC(General Use)
TV-8 
DEMKO Approved Models 153445-03(EN61058-1) 16A 125V AC(Resistive)
16A 250V AC(Resistive) 
A8GS UL/C-UL (CSA) Approved Models (Recognized) E41515(UL610581
/CSAC22.2No.61058-1)
16A 125V AC(Resistive)
10A 250V AC(Resistive)
TV-8 (only model numbers with V in suffix)
TÜV Approved Models R 50209538(EN61058-1) 10(4)A 250VAC(Power contact)
0.2A 5VDC(Signal contact)
8/128A 250VAC (only model numbers with V in suffix)
A8GS-T UL/C-UL (CSA) Approved Models (Recognized) E41515(UL61058-1
/CSAC22.2No.61058-1)
16A 125V AC(Resistive)
10A 250V AC(Resistive) 
TÜV Approved Models R 5020953-8(EN61058-1) 10(4)A 250VAC(Power contact)
0.2A 5VDC(Signal contact) 

| Micro Switch | Rocker Switch | Pushbutton Switch |

Pushbutton Switch

 

Model Standards Standard No. Rating
A16 UL/C-UL (CSA) Approved Models (Recognized) E41515(UL508/CSAC22.2
No.14)
5A 125V AC(General Use)
3A 250V AC(General Use)
3A 30V DC(Resistive) 
TÜV Approved Models Ask your OMRON representative. (EN60947-5-1) 3A 250V AC
3A 30V DC 
CCC Approved Models 2003010303070678
(GB14048.5)
5A 125V AC
3A 250V AC
3A 30V DC 
A3A□-9□K
A3A□-9□L
UL Approved Models (Recognized)  E41515(UL508) 6A 125V AC、2A 250V AC(General Use)
4A 30V DC(Resistive) 
CSA Approved Models (Certified) LR45258(CSAC22.2
(No.14))
6A 125V AC、2A 250V AC(General Use)
4A 30V DC(Resistive) 
CCC Approved Models 2015010305817221
2015010305817277
2015010305817268
2015010305817274
(GB14048.5)
6A 125V AC、2A 250V AC
4A 30V DC
A3A□-9□A
A3A□-9□B
UL Approved Models (Recognized)  E41515(UL508) 3A 125V AC(General Use)
2A 30V DC(Resistive) 
CSA Approved Models (Certified) LR45258(CSAC22.2
(No.14))
3A 125V AC(General Use)
2A 30V DC(Resistive) 
CCC Approved Models 2015010305817221
2015010305817277
2015010305817268
2015010305817274
(GB14048.5)
3A 125V AC
2A 30V DC
A3C UL Approved Models (Recognized) E41515(UL508) Standard load 1A 125 V AC、0.5A 250V AC
(General Use)
1A 30V DC(Resistive)
Microload 0.1A 125V AC(General Use)
0.1A 30V DC(Resistive)
CSA Approved Models (Certified) LR45258(CSAC22.2
(No.14))
Standard load 1A 125V AC、0.5A 250V AC
(General Use)
1A 30V DC(Resistive)
Microload 0.1A 125V AC(General Use)
0.1A 30V DC(Resistive)
CCC Approved Models 2010010305398682
(GB14048.5)
Standard load 0.5A 250V AC
Microload 0.1A 125V AC
M2C UL Approved Models (Recognized) E41515(UL508) LED lamp 24V DC max.
Incandescent lamp 28V AC/DC 1W max.
CSA Approved Models (Certified) LR45258(CSAC22.2
(No.14))
LED lamp 24V DC max.
Incandescent lamp 28V AC/DC 1W max.

PCB CONNECTOR

Series Model Standards Standard No. Rating
XC4A XC4A-4812 UL/C-UL Approved Models
(Recognized)
E103202
XC4B XC4B-4811 UL/C-UL Approved Models
(Recognized)
E103202
XC4B-4813 UL/C-UL Approved Models
(Recognized)
E103202
XC4E XC4E-3212 UL/C-UL Approved Models
(Recognized)
E103202
XC4E-4812 UL/C-UL Approved Models
(Recognized)
E103202
XC4F XC4F-3213 UL/C-UL Approved Models
(Recognized)
E103202
XC4F-4813 UL/C-UL Approved Models
(Recognized)
E103202
XC4G XC4G-3212 UL/C-UL Approved Models
(Recognized)
E103202
XC4H XC4H-3213 UL/C-UL Approved Models
(Recognized)
E103202
XC4K XC4K-1542 UL/C-UL Approved Models
(Recognized)
E103202
XC4L XC4L-1546 UL/C-UL Approved Models
(Recognized)
E103202
XC4L-1541 UL/C-UL Approved Models
(Recognized)
E103202
XC5A XC5A-□□22 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5A-□□82-1 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5A-1682-1 UL Approved Models
(Recognized)
E103202 300V 2A
XC5B XC5B-□□21 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5B-□□23 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5B-□□31-0 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5B-1031-0 UL Approved Models
(Recognized)
E103202 300V 2A
XC5B-1431-0 UL Approved Models
(Recognized)
E103202 300V 2A
XC5B-1631-0 UL Approved Models
(Recognized)
E103202 300V 2A
XC5B-□□31-3 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5B-1031-3 UL Approved Models
(Recognized)
E103202 300V 2A
XC5B-1431-3 UL Approved Models
(Recognized)
E103202 300V 2A
XC5B-1631-3 UL Approved Models
(Recognized)
E103202 300V 2A
XC5B-□□2P-11□□ UL Approved Models
(Recognized)
E103202 300V 2A
XC5C XC5C-□□22 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5C-□□82-1 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5D XC5D-□□21 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5D-□□23 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5D-□□31-0 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5D-□□2P-11□□ UL Approved Models
(Recognized)
E103202 300V 2A
XC5E XC5E-□□21 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5E-□□23 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5E-□□81-2 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5E-1081-2 UL Approved Models
(Recognized)
E103202 300V 2A
XC5E-1481-2 UL Approved Models
(Recognized)
E103202 300V 2A
XC5E-□□81-3 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5E-1081-3 UL Approved Models
(Recognized)
E103202 300V 2A
XC5E-1481-3 UL Approved Models
(Recognized)
E103202 300V 2A
XC5E-□□2P-11□□ UL Approved Models
(Recognized)
E103202 300V 2A
XC5E-□□ Non Approved Models
XC5F XC5F-□□22 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5F-□□32-2 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5G XC5G-□□21 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5G-□□23 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5G-□□2P-11□□ UL Approved Models
(Recognized)
E103202 300V 2A
XC5G-□□ Non Approved Models
XC5H XC5H-□□22 UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E103202
LR 62678
300V 2A
XC5K XC5K-□□31-2A Non Approved Models
XC5K-□□31-3A Non Approved Models
XC5M XC5M-0222 Non Approved Models
XC5M-0222-1 Non Approved Models
XC5N XC5N-0221 Non Approved Models
XC5T XC5T-962 Non Approved Models
XC5T-963 Non Approved Models
XC5Z XC5Z-□□□□ Non Approved Models
XC7A XC7A-□□42-□□□□ Non Approved Models
XC7B XC7B-□□41-□□□□ Non Approved Models
XC7C XC7C-9642-□□□□ Non Approved Models
XC7D XC7D-9641-□□□□ Non Approved Models
XC8A XC8A-1101S-0 UL/C-UL Approved Models
(Recognized)
E103202
XC8A-1101S-ACP UL/C-UL Approved Models
(Recognized)
E103202
XC8A-1101S-AWP UL/C-UL Approved Models
(Recognized)
E103202
XC8A-1101S-4 UL/C-UL Approved Models
(Recognized)
E103202
XC8A-1100 UL/C-UL Approved Models
(Recognized)
E103202
XC8A-1101 UL/C-UL Approved Models
(Recognized)
E103202
XC8A-1102 UL/C-UL Approved Models
(Recognized)
E103202
XC8B XC8B-1101L UL/C-UL Approved Models
(Recognized)
E103202
XC8B-1101L-NN UL/C-UL Approved Models
(Recognized)
E103202
XC8C XC8C-0951S-0 UL/C-UL Approved Models
(Recognized)
E103202
XC8C-01101S-0 UL/C-UL Approved Models
(Recognized)
E103202
XC8C-1101S-AC UL/C-UL Approved Models
(Recognized)
E103202
XC8C-1101S-AW UL/C-UL Approved Models
(Recognized)
E103202
XC8C-1251S-AC UL/C-UL Approved Models
(Recognized)
E103202
XC8C-1251S-AW UL/C-UL Approved Models
(Recognized)
E103202
XC8C-0951S-4 UL/C-UL Approved Models
(Recognized)
E103202
XC8C-1101S-4 UL/C-UL Approved Models
(Recognized)
E103202
XC8C-0950 UL/C-UL Approved Models
(Recognized)
E103202
XC8C-0951 UL/C-UL Approved Models
(Recognized)
E103202
XC8C-0952 UL/C-UL Approved Models
(Recognized)
E103202
XC8C-1100 UL/C-UL Approved Models
(Recognized)
E103202
XC8C-1101 UL/C-UL Approved Models
(Recognized)
E103202
XC8C-1102 UL/C-UL Approved Models
(Recognized)
E103202
XC8D XC8D-0951L UL/C-UL Approved Models
(Recognized)
E103202
XC8D-0951L-NN UL/C-UL Approved Models
(Recognized)
E103202
XC8D-1101L UL/C-UL Approved Models
(Recognized)
E103202
XC8D-1101L-NN UL/C-UL Approved Models
(Recognized)
E103202
XC8D-1251L-SN UL/C-UL Approved Models
(Recognized)
E103202
XC8D-1251L-NN UL/C-UL Approved Models
(Recognized)
E103202
XC8E XC8E-0551S-ACP UL/C-UL Approved Models
(Recognized)
E103202
XC8E-0551S-AWP UL/C-UL Approved Models
(Recognized)
E103202
XC8F XC8F-0551L-SN UL/C-UL Approved Models
(Recognized)
E103202
XC8F-0551L-NN UL/C-UL Approved Models
(Recognized)
E103202
XC8K XC8K-1251S-AC UL/C-UL Approved Models
(Recognized)
E103202
XC8L XC8L-1251L-SN UL/C-UL Approved Models
(Recognized)
E103202
XC8Y XC8Y-□□□□L Non Approved Models
XC8Z XC8Z-00□□ Non Approved Models
XF2M XF2M-□□15-1A Non Approved Models
XF2M-□□15-1AH Non Approved Models
XF3M XF3M-□□15-1B Non Approved Models
XF3M-8015-1BE Non Approved Models
XF3M-□□15-1B-R100 Non Approved Models
XF3M-8015-1BE-R100 Non Approved Models
XF3M-□□15-1D Non Approved Models
XF3M-□□15-1D-R100 Non Approved Models
XF3M-□□25-1B Non Approved Models
XF3M-□□25-1B-R100 Non Approved Models
XF3M(1) XF3M(1)-□□15-1B Non Approved Models
XF3M(1)-□□15-1B-R100 Non Approved Models
XF3M(1)-□□15-1D Non Approved Models
XF3M(1)-□□15-1D-R100 Non Approved Models
XG2A XG2A-□□01 Non Approved Models
XG2A-□□02 Non Approved Models
XG4A XG4A-□□31/-□□71 UL Approved Models
(Recognized)
E103202 300Vac/dc 3A
XG4A-□□34/-□□74 UL Approved Models
(Recognized)
E103202 300Vac/dc 3A
XG4A-□□32/-□□72 UL Approved Models
(Recognized)
E103202 300Vac/dc 3A
XG4A-□□35/-□□75 UL Approved Models
(Recognized)
E103202 300Vac/dc 3A
XG4A-□□33/-□□73 UL Approved Models
(Recognized)
E103202 300Vac/dc 3A
XG4A-□□36/-□□76 Non Approved Models
XG4A-□□39-A Non Approved Models
XG4A-□□79-A Non Approved Models
XG4C XG4C-□□31/-□□71 UL Approved Models
(Recognized)
E103202 300Vac/dc 3A
XG4C-□□34/-□□74 UL Approved Models
(Recognized)
E103202 300Vac/dc 3A
XG4E XG4E-□□31/-□□71 UL Approved Models
(Recognized)
E103202
XG4E-□□32/-□□72 UL Approved Models
(Recognized)
E103202
XG4H XG4H-□□31/-□□71 UL Approved Models
(Recognized)
E103202 150Vac/dc 1A
XG4H-3431-1 UL Approved Models
(Recognized)
E103202 150Vac/dc 1A
XG4H-4031-1 UL Approved Models
(Recognized)
E103202 150Vac/dc 1A
XG4H-4034 UL Approved Models
(Recognized)
E103202 150Vac/dc 1A
XG4M XG4M-□□30 UL Approved Models
(Recognized)
E103202 250Vac/dc 1A
XG4M-□□31 UL Approved Models
(Recognized)
E103202 250Vac/dc 1A
XG4M-□□30ーT Non Approved Models
XG4M-□□31ーT Non Approved Models
XG4M-□□30ーU Non Approved Models
XG4M-□□31ーU Non Approved Models
XG4S XG4S-□□04 UL Approved Models
(Recognized)
E103202
XG4T XG4T-□□04 UL Approved Models
(Recognized)
E103202
XG4U XG4U-□□04 Non Approved Models
XG4Z XG4Z-□□□□ Non Approved Models
XG5M XG5M-1031-N UL Approved Models
(Recognized)
E103202
XG5M-1034-N UL Approved Models
(Recognized)
E103202
XG5M-□□32-N UL Approved Models
(Recognized)
E103202
XG5M-□□33-N UL Approved Models
(Recognized)
E103202
XG5M-□□35-N UL Approved Models
(Recognized)
E103202
XG5M-□□36-N UL Approved Models
(Recognized)
E103202
XG5N XG5N-100 UL/C-UL Approved Models
(Recognized)
E103202 200Vac 1A
XG5N-□□1 UL/C-UL Approved Models
(Recognized)
E103202 200Vac 1A
XG5N-□□2 UL/C-UL Approved Models
(Recognized)
E103202 200Vac 1A
XG5N-100-U Non Approved Models
XG5N-□□1ーU Non Approved Models
XG5N-□□2ーU Non Approved Models
XG5S XG5S-□□01 Non Approved Models
XG5S-□□12 Non Approved Models
XG5S-□□22 Non Approved Models
XG5U XG5U-0001 Non Approved Models
XG5W XG5W-0031-N Non Approved Models
XG5W-0034-N Non Approved Models
XG5W XG5W-0231 Non Approved Models
XG5W-0231-R Non Approved Models
XG5W-0232 Non Approved Models
XG5W-0232-R Non Approved Models
XG5Z XG5Z-□□□□ Non Approved Models
XG8A XG8A-5031 UL Approved Models
(Recognized)
E103202 300V 3A
XG8A-5034 UL Approved Models
(Recognized)
E103202 300V 3A
XG8B XG8B-0131 UL Approved Models
(Recognized)
E103202 300V 3A
XG8B-0134 UL Approved Models
(Recognized)
E103202 300V 3A
XG8S XG8S-□□31 Non Approved Models
XG8S-□□41 Non Approved Models
XG8T XG8T-□□31 Non Approved Models
XG8T-□□41 Non Approved Models
XG8V XG8V-□□31 UL/C-UL Approved Models
(Recognized)
E103202 300Vac 1A
XG8V-□□41 UL/C-UL Approved Models
(Recognized)
E103202 300Vac 1A
XG8V-□□34 UL/C-UL Approved Models
(Recognized)
E103202 300Vac 1A
XG8V-□□44 UL/C-UL Approved Models
(Recognized)
E103202 300Vac 1A
XG8W XG8W-□□31 UL/C-UL Approved Models
(Recognized)
E103202 300Vac 1A
XG8W-□□41 UL/C-UL Approved Models
(Recognized)
E103202 300Vac 1A
XG8W-□□34 UL/C-UL Approved Models
(Recognized)
E103202 300Vac 1A
XG8W-□□44 UL/C-UL Approved Models
(Recognized)
E103202 300Vac 1A
XH2A XH2A-□□41 UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH2A-□□41-A UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH2A-□□42 UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH2A-□□42-A UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH2B XH2B-□□41 UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH2B-□□41-A UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH2B-□□42 UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH2B-□□42-A UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH3A XH3A-□□41 UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH3A-□□41-A UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH3A-□□41-2A UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH3A-□□41-4A UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH3A-□□42-A UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH3B XH3B-□□41 UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH3B-□□41-A UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH3B-□□41-1A UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH3B-□□41-3A UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH3B-□□41-4A UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH3B-□□42-A UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH4A XH4A-□□31 UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH4A-□□31-A UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH4A-□□31-1A UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH4A-□□31-2A UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH4A-□□31-3A UL Approved Models
(Recognized)
E103202 29.9V 0.5A
XH4A-□□35-A Non Approved Models
XH4A-□□35-1A Non Approved Models
XH4A-□□35-2A Non Approved Models
XH5A XH5A-□□15-N UL Approved Models
(Recognized)
E103202
XH5A-□□16-N UL Approved Models
(Recognized)
E103202
XH5B XH5B-□□15-□N UL Approved Models
(Recognized)
E103202
XH5B-□□16-□N UL Approved Models
(Recognized)
E103202
XH5E XH5E-□□15-□N UL Approved Models
(Recognized)
E103202
XH5E-□□16-□N UL Approved Models
(Recognized)
E103202
XH5F XH5F-□□15-N UL Approved Models
(Recognized)
E103202
XH5H XH5H-□□10-□□N Non Approved Models
XH5M XH5M-□□10-N Non Approved Models
XH5T XH5T-□□04-N Non Approved Models
XJ8A XJ8A-0211 UL Approved Models
(Recognized)
E103202
XJ8A-0241 UL Approved Models
(Recognized)
E103202
XJ8A-0214 UL Approved Models
(Recognized)
E103202
XJ8B XJ8B-□□11 UL Approved Models
(Recognized)
E103202
XJ8C XJ8C-□□11 UL Approved Models
(Recognized)
E103202
XJ8D XJ8D-□□11 UL Approved Models
(Recognized)
E103202
XM2C-L XM2C-□□42-502L UL Approved Models
(Recognized)
E103202
XM2C-□□42-1□2L UL Approved Models
(Recognized)
E103202
XM2E-L XM2E-□□40-L UL Approved Models
(Recognized)
E103202
XM2E-□□40-502L UL Approved Models
(Recognized)
E103202
XM2E-□□40-1□2L UL Approved Models
(Recognized)
E103202
XM2F-L XM2F-□□40-L UL Approved Models
(Recognized)
E103202
XM2F-□□40-502L UL Approved Models
(Recognized)
E103202
XM2F-□□40-1□2L UL Approved Models
(Recognized)
E103202
XM2S XM2S-□□11 Non Approved Models
XM2S-□□12 Non Approved Models
XM2S-□□13 Non Approved Models
XM2S-2521 Non Approved Models
XM2S-2522 Non Approved Models
XM2S-2523 Non Approved Models
XM2S-0921 Non Approved Models
XM2S-0922 Non Approved Models
XM2S-0923 Non Approved Models
XM2S-0911-E Non Approved Models
XM2T XM2T-□□□□ Non Approved Models
XM2T-□□□□-0 Non Approved Models
XM2Z XM2Z-□□□□ Non Approved Models
XM3A XM3A-□□21 UL/C-UL Approved Models
(Recognized)
E103202 300Vac 1.5A
XM3B XM3B-□□22 UL Approved Models
(Recognized)
E103202 300V 5A
XM3B-□□22-501 UL Approved Models
(Recognized)
E103202 300V 5A
XM3B-□□22-111 UL Approved Models
(Recognized)
E103202 300V 5A
XM3B-□□22-131 UL Approved Models
(Recognized)
E103202 300V 5A
XM3B-□□22-502 UL Approved Models
(Recognized)
E103202 300V 5A
XM3B-□□22-112 UL Approved Models
(Recognized)
E103202 300V 5A
XM3B-□□22-132 UL Approved Models
(Recognized)
E103202 300V 5A
XM3B-L XM3B-□□42-502L UL Approved Models
(Recognized)
E103202
XM3B-□□42-1□2L UL Approved Models
(Recognized)
E103202
XM3B-LS XM3B-0942-1□2LS Non Approved Models
XM3C XM3C-□□22 UL/C-UL Approved Models
(Recognized)
E103202 300Vac 1.5A
XM3C-□□22-501 UL/C-UL Approved Models
(Recognized)
E103202 300Vac 1.5A
XM3C-□□22-502 UL/C-UL Approved Models
(Recognized)
E103202 300Vac 1.5A
XM3C-□□22-111 UL/C-UL Approved Models
(Recognized)
E103202 300Vac 1.5A
XM3C-□□22-112 UL/C-UL Approved Models
(Recognized)
E103202 300Vac 1.5A
XM3C-LS XM3C-0942-1□2LS Non Approved Models
XM3D XM3D-□□21 UL/C-UL Approved Models
(Recognized)
E103202 300Vac 1.5A
XM3F XM3F-□□20 UL/C-UL Approved Models
(Recognized)
E103202 300Vac 1.5A
XM3F-□□20-112 UL/C-UL Approved Models
(Recognized)
E103202 300Vac 1.5A
XM3K XM3K-□□12-02N UL/C-UL Approved Models
(Recognized)
E103202
XM3K-□□12-03N UL/C-UL Approved Models
(Recognized)
E103202
XM3K-□□12-12N UL/C-UL Approved Models
(Recognized)
E103202
XM3K-□□12-13N UL/C-UL Approved Models
(Recognized)
E103202
XM3L XM3L-□□12-02N UL/C-UL Approved Models
(Recognized)
E103202
XM3L-□□12-03N UL/C-UL Approved Models
(Recognized)
E103202
XM3L-□□12-12N UL/C-UL Approved Models
(Recognized)
E103202
XM3L-□□12-13N UL/C-UL Approved Models
(Recognized)
E103202
XM4K XM4K-1542-502 UL Approved Models
(Recognized)
E103202
XM4K-1542-1□2 UL Approved Models
(Recognized)
E103202
XM4L XM4L-1542-502 UL Approved Models
(Recognized)
E103202
XM4L-1542-1□2 UL Approved Models
(Recognized)
E103202
XM4L-1541-502 UL Approved Models
(Recognized)
E103202
XM4L-1541-1□2 UL Approved Models
(Recognized)
E103202
XM4Z XM4Z-□□□□ Non Approved Models
XM7A XM7A-0441 Non Approved Models
XM7A-0442 Non Approved Models
XM7A-0442-A Non Approved Models
XM7B XM7B-0442 Non Approved Models
XM7D XM7D-0512 Non Approved Models
XM7D-0514 Non Approved Models
XM7D-0514-R Non Approved Models
XM7Z XM7Z-0001 Non Approved Models
XM7Z-0002 Non Approved Models
XM9B XM9B-18844-10 Non Approved Models
XM9B-18844-11 Non Approved Models
XN2A XN2A-1□70 UL/C-UL Approved Models
(Recognized)
E103202 28AWG、26AWG :30Vdc 0.5A
24AWG、      :30Vdc 1A
22AWG       :30Vdc 2A
20AWG       :30Vdc 3A
XN2B XN2B-1470 UL/C-UL Approved Models
(Recognized)
E103202 28AWG、26AWG :30Vdc 0.5A
24AWG、      :30Vdc 1A
22AWG       :30Vdc 2A
20AWG       :30Vdc 3A
XN2D XN2D-1□71 UL/C-UL Approved Models
(Recognized)
E103202 32Vdc 3A
XN2D-4471 UL/C-UL Approved Models
(Recognized)
E103202 32Vdc 1A
XN2Z XN2Z-0001 Non Approved Models
XR2A XR2A-□□11-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2A-2463-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2A-2473-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2A-□□01-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2A-2461-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2A-2471-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2A-□□21-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2A-2467-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2A-2477-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2A-□□02 UL Approved Models
(Recognized)
E103202 300V 1A
XR2A-□□15 UL Approved Models
(Recognized)
E103202 300V 1A
XR2A-2466 UL Approved Models
(Recognized)
E103202 300V 1A
XR2A-2476 UL Approved Models
(Recognized)
E103202 300V 1A
XR2A-□□05 UL Approved Models
(Recognized)
E103202 300V 1A
XR2A-□□25 UL Approved Models
(Recognized)
E103202 300V 1A
XR2A-2468 UL Approved Models
(Recognized)
E103202 300V 1A
XR2A-2478 UL Approved Models
(Recognized)
E103202 300V 1A
XR2B XR2B-□□11-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2B-□□01-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2C XR2C-□□□1-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2C-□□□5 UL Approved Models
(Recognized)
E103202 300V 1A
XR2C-□□□2 UL Approved Models
(Recognized)
E103202 300V 1A
XR2T XR2T-□□11-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2T-2473-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2T-□□01-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2T-2471-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2T-□□21-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2T-2477-N UL Approved Models
(Recognized)
E103202 300V 1A
XR2P XR2P-□□41 Non Approved Models
XR2Z XR2Z-□□ Non Approved Models
XR3G XR3G-□□□1 Non Approved Models
XW4A XW4A-□□B1-H1 UL/C-UL Approved Models
(Recognized)
E245101 300V 8A
XW4A-□□B1-V1 UL/C-UL Approved Models
(Recognized)
E245101 300V 8A
XW4A-□□C1-H1 UL/C-UL Approved Models
(Recognized)
E245101 300V 10A
XW4A-□□C1-V1 UL/C-UL Approved Models
(Recognized)
E245101 300V 10A
XW4B XW4B-□□B1-H1 UL/C-UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E245101 300V 8A
XW4B-□□C1-H1 UL/C-UL Approved Models
(Recognized)
CSA Approved Models
(Certified)
E245101 300V 15A
XW4C XW4C-□□D1-H1 Non Approved Models
XW4C-□□D1-V1 Non Approved Models
XW4C-□□E1-H1 Non Approved Models
XW4C-□□E1-V1 Non Approved Models
XW4E XW4E-□□B1-V1 UL/C-UL Approved Models
(Recognized)
E245101 300V 10A
XW4E-□□B1-S1 UL/C-UL Approved Models
(Recognized)
E245101 300V 10A
XW4E-□□B2-V1 UL/C-UL Approved Models
(Recognized)
E245101 300V 10A
XW4E-□□C1-V1 UL/C-UL Approved Models
(Recognized)
E245101 300V 10A
XW4E-□□C1-S1 UL/C-UL Approved Models
(Recognized)
E245101 300V 10A
XW4E-□□C2-V1 UL/C-UL Approved Models
(Recognized)
E245101 300V 10A
XW4H XW4H-□□A1 UL/C-UL Approved Models
(Recognized)
E103202
XW4K XW4K-□□A1-V1 UL/C-UL Approved Models
(Recognized)
E103202
XW4K-□□A1-H1 UL/C-UL Approved Models
(Recognized)
E103202
XW4K-□□A1-V1-R100 UL/C-UL Approved Models
(Recognized)
E103202
XW4K-□□A1-H1-R100 UL/C-UL Approved Models
(Recognized)
E103202
XW4L XW4L-□□A1-V1 UL/C-UL Approved Models
(Recognized)
E103202
XW4L-□□A1-H1 UL/C-UL Approved Models
(Recognized)
E103202
XW4L-□□A1-V1-R100 UL/C-UL Approved Models
(Recognized)
E103202
XW4L-□□A1-H1-R100 UL/C-UL Approved Models
(Recognized)
E103202
XW4M XW4M-□□D1-V1D□ UL/C-UL Approved Models
(Recognized)
E245101  UG:B,D 300V 8A
XW4M-□□D1-H1D□ UL/C-UL Approved Models
(Recognized)
E245101  UG:B,D 300V 8A
XW4M-□□D2-V1D□ UL/C-UL Approved Models
(Recognized)
E245101  UG:B 150V 8A
UG:D 300V 8A
XW4M-□□D2-H1D□ UL/C-UL Approved Models
(Recognized)
E245101  UG:B 150V 8A
UG:D 300V 8A
XW4N XW4N-□□D1-□ UL/C-UL Approved Models
(Recognized)
E245101  UG:B,D 300V 8A
XW4N-□□D2-□ UL/C-UL Approved Models
(Recognized)
E245101  UG:B,D 300V 8A
XW4Z XW4Z-□□□ Non Approved Models
XY2□ XY2□ Non Approved Models
XY3□ XY3□ Non Approved Models
XZ2F XZ2F-□□□□□-□□□□ Non Approved Models

Environment Sensor

Model Display of CE Conformity Note Download
2JCIE-BL01
  Declaration of conformity
2JCIE-BU01
  Declaration of conformity