D2S Subminiature Basic Switch
Subminiature Switch with Superb Flux Resistance
- One-piece terminal construction to keep out flux.
- High operating-position accuracy (±0.25 mm) enables easy peripheral design and positioning.
Use of pin plunger also allows horizontal operation.
Model | 2D/3D CAD | |
---|---|---|
D2S-01 | Download | |
D2S-01-F | Download | |
D2S-01-FD | Download | |
D2S-01D | Download | |
D2S-01L | Download | |
D2S-01L-F | Download | |
D2S-01L-FD | Download | |
D2S-01L13 | Download | |
D2S-01L13-F | Download | |
D2S-01L13-FD | Download | |
D2S-01L13D | Download | |
D2S-01L2 | Download | |
D2S-01L2-F | Download | |
D2S-01L2-FD | Download | |
D2S-01L2D | Download | |
D2S-01LD | Download | |
D2S-10 | Download | |
D2S-10L | Download | |
D2S-10L13 | Download | |
D2S-10L13D | Download | |
D2S-10L2 | Download | |
D2S-10L2D | Download | |
D2S-10LD | Download | |
D2S-5 | Download | |
D2S-5-F | Download | |
D2S-5-FD | Download | |
D2S-5D | Download | |
D2S-5L | Download | |
D2S-5L-F | Download | |
D2S-5L-FD | Download | |
D2S-5L13 | Download | |
D2S-5L13-F | Download | |
D2S-5L13-FD | Download | |
D2S-5L13D | Download | |
D2S-5L2 | Download | |
D2S-5L2-F | Download | |
D2S-5L2-FD | Download | |
D2S-5L2D | Download | |
D2S-5LD | Download |

Actuator | Terminals | OF max |
Model | ||
---|---|---|---|---|---|
10.1 A | 5 A | 0.1 A | |||
Pin plunger
|
Solder terminals
|
1.47 N {150 gf}
|
D2S-10 | D2S-5 | D2S-01 |
0.49 N {50 gf}
|
--- | D2S-5-F | D2S-01-F | ||
Self-clinching PCB terminals
|
1.47 N {150 gf}
|
D2S-10D | D2S-5D | D2S-01D | |
0.49 N {50 gf}
|
--- | D2S-5-FD | D2S-01-FD | ||
Hinge lever
|
Solder terminals
|
0.49 N {50 gf}
|
D2S-10L | D2S-5L | D2S-01L |
0.18 N {18 gf}
|
--- | D2S-5L-F | D2S-01L-F | ||
Self-clinching PCB terminals
|
0.49 N {50 gf}
|
D2S-10LD | D2S-5LD | D2S-01LD | |
0.18 N {18 gf}
|
--- | D2S-5L-FD | D2S-01L-FD | ||
Simulated roller lever
|
Solder terminals
|
0.49 N {50 gf}
|
D2S-10L13 | D2S-5L13 | D2S-01L13 |
0.18 N {18 gf}
|
--- | D2S-5L13-F | D2S-01L13-F | ||
Self-clinching PCB terminals
|
0.49 N {50 gf}
|
D2S-10L13D | D2S-5L13D | D2S-01L13D | |
0.18 N {18 gf}
|
--- | D2S-5L13-FD | D2S-01L13-FD | ||
Hinge roller lever
|
Solder terminals
|
0.49 N {50 gf}
|
D2S-10L2 | D2S-5L2 | D2S-01L2 |
0.18 N {18 gf}
|
--- | D2S-5L2-F | D2S-01L2-F | ||
Self-clinching PCB terminals
|
0.49 N {50 gf}
|
D2S-10L2D | D2S-5L2D | D2S-01L2D | |
0.18 N {18 gf}
|
--- | D2S-5L2-FD | D2S-01L2-FD |
Contact Form
SPDT
|
Resisteve load
|
|||||
---|---|---|---|---|---|---|
D2S-10 | 250VAC | 10.1A | ||||
D2S-5 | 125VAC 250VAC |
5A 3A |
||||
D2S-01 | 125VAC | 0.1A | ||||
30VDC | 0.1A |
Note: | The rating values apply under the following test conditions: Ambient temperature:20±2°C Ambient humidity:65±5% Operating frequency:30 operations/min |
Characteristics
Permissible operating speed
|
0.1 mm to 1 m/s (pin plunger models) | ||||||
---|---|---|---|---|---|---|---|
Permissible operating frequency
|
|
||||||
Insulation resistance
|
100 MΩmin. (at 500 VDC) | ||||||
Contact resistance
(initial value) |
|
||||||
Dielectric strength * 1
|
1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity 1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground 1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal parts |
||||||
Vibration resistance * 2
|
Malfunction:10 to 55 Hz, 1.5-mm double amplitude | ||||||
Shock resistance
|
|
||||||
Durability * 3
|
|
||||||
Degree of protection
|
IEC IP40 | ||||||
Degree of protection against electric shock
|
Class I | ||||||
Proof tracking index (PTI)
|
175 | ||||||
Ambient operating temperature
|
-25º to +85ºC (at ambient humidity of 60% max.) (with no icing or condensation) |
||||||
Ambient operating humidity
|
85% max. (for +5ºC to +35ºC) | ||||||
Weight
|
Approx. 1.6 g (pin plunger models) |
Note: | The data given above are initial values. | |
*1 | The values for dielectric strength shown are for models with a Separator (refer to "Micro Switch Common Accessories"). | |
*2 | The values are at Free Position and Total Travel Position values for pin plunger, and Total Travel Position value for lever. Close or open circuit of the contact is 1ms max. |
|
*3 | For testing conditions, consult your OMRON sales representative. |
(Unit: mm)
|
|||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||
|
Cautions
●Soldering
·When using automatic soldering baths, we recommend soldering at 260±5°C within 5 seconds. Make sure that the liquid surface of the solder does not flow over the edge of the board. When soldering terminals manually, complete the soldering at the iron tip temperature between 350 to 400°C within 3 seconds, and do not apply any external force for 1 minute after soldering. When applying solder, keep the solder away from the case of the Switch and do not allow solder or flux to flow into the case.
Correct Use
●Mounting
·Use M2.3 mounting screw with plane washers or spring washers
to securely mount the Switch. Tighten the screws to a torque of 0.23 to 0.26 Nm {2.3 to 2.7 kgfcm}.
●Using Micro Loads
Using a model for ordinary loads to open or close the contact of a micro load circuit may result in faulty contact. Use models that operate in the following range. However, even when using micro load models within the following operating range, if inrush current occurs when the contact is opened or closed, it may increase the contact wear and so decrease durability. Therefore, insert a contact protection circuit where necessary. The N-level reference value applies for the minimum applicable load. This value indicates the malfunction reference level for the reliability level of 60% (λ60).
(JIS C5003)
The equation, λ60=0.5×10-6/operations indicates that the estimated malfunction rate is less than 1/ 2,000,000 operations with a reliability level of 60%.