D3SH Surface Mount Detection Switch
The smallest detection switch in the world. Ideal for miniature mobile devices
- Ultra small size and ultra low profile contributing to down-sizing of sets devices.(3.0 × 3.4 × 0.9 mm (W × D × H))
- A unique mechanism enables high contact reliability and high precision operation.
- Horizontal 2-way detection and long stroke for easy installation are available.
- Meet a variety of applications by contact and lever variations.
Model | 2D/3D CAD | |
---|---|---|
D3SH-A0L | Download | |
D3SH-A0L1 | Download | |
D3SH-A0R | Download | |
D3SH-A0R1 | Download | |
D3SH-A1L | Download | |
D3SH-A1L1 | Download | |
D3SH-A1R | Download | |
D3SH-A1R1 | Download | |
D3SH-B0L | Download | |
D3SH-B0L1 | Download | |
D3SH-B0R | Download | |
D3SH-B0R1 | Download | |
D3SH-B1L | Download | |
D3SH-B1L1 | Download | |
D3SH-B1R | Download | |
D3SH-B1R1 | Download |

Standard Lever Models
Contact form
|
Direction of Operation | Boss of Positioning |
Model | Minimum packing unit* | |
---|---|---|---|---|---|
SPST-NO | Right | With Boss | D3SH-A1R | 1,000 pcs. | |
D3SH-A1R-6 | 6,000 pcs. | ||||
Without Boss | D3SH-A0R | 1,000 pcs. | |||
D3SH-A0R-6 | 6,000 pcs. | ||||
Left | With Boss | D3SH-A1L | 1,000 pcs. | ||
D3SH-A1L-6 | 6,000 pcs. | ||||
Without Boss | D3SH-A0L | 1,000 pcs. | |||
D3SH-A0L-6 | 6,000 pcs. | ||||
SPST-NC | Right | With Boss | D3SH-B1R | 1,000 pcs. | |
D3SH-B1R-6 | 6,000 pcs. | ||||
Without Boss | D3SH-B0R | 1,000 pcs. | |||
D3SH-B0R-6 | 6,000 pcs. | ||||
Left | With Boss | D3SH-B1L | 1,000 pcs. | ||
D3SH-B1L-6 | 6,000 pcs. | ||||
Without Boss | D3SH-B0L | 1,000 pcs. | |||
D3SH-B0L-6 | 6,000 pcs. |
*Products are packed with embossed tape. |
Long Lever Models
Contact form
|
Direction of Operation | Boss of Positioning |
Model | Minimum packing unit* | |
---|---|---|---|---|---|
SPST-NO | Right | With Boss | D3SH-A1R1 | 1,000 pcs. | |
D3SH-A1R1-6 | 6,000 pcs. | ||||
Without Boss | D3SH-A0R1 | 1,000 pcs. | |||
D3SH-A0R1-6 | 6,000 pcs. | ||||
Left | With Boss | D3SH-A1L1 | 1,000 pcs. | ||
D3SH-A1L1-6 | 6,000 pcs. | ||||
Without Boss | D3SH-A0L1 | 1,000 pcs. | |||
D3SH-A0L1-6 | 6,000 pcs. | ||||
SPST-NC | Right | With Boss | D3SH-B1R1 | 1,000 pcs. | |
D3SH-B1R1-6 | 6,000 pcs. | ||||
Without Boss | D3SH-B0R1 | 1,000 pcs. | |||
D3SH-B0R1-6 | 6,000 pcs. | ||||
Left | With Boss | D3SH-B1L1 | 1,000 pcs. | ||
D3SH-B1L1-6 | 6,000 pcs. | ||||
Without Boss | D3SH-B0L1 | 1,000 pcs. | |||
D3SH-B0L1-6 | 6,000 pcs. |
*Products are packed with embossed tape. |
Rated voltage | Resistive load |
---|---|
5 VDC | 1 mA |
Note: | The ratings values apply under the following test conditions: | ||||||
|
Characteristics
Permissible operating speed
|
1 mm to 300 mm/s |
---|---|
Permissible operating frequency
|
Mechanical: 60 operations/min max. Electrical: 60 operations/min max. |
Insulation resistance
|
100 MΩ min. (at 100 VDC) |
Contact resistance (initial value)
|
3 Ω max. |
Dielectric strength
|
100 VAC for 1 min between terminals of same polarity |
Vibration resistance *1
|
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude |
Shock resistance
|
Destruction: 1000 m/s2 {approx. 100 G} max. Malfunction*1: 300 m/s2 {approx. 30 G} max. |
Durability *2
|
Mechanical: 150,000 operations min. (20 operations/min.) Electrical: 100,000 operations min. (20 operations/min.) |
Degree of protection
|
IEC IP40 |
Ambient operating temperature
|
-25ºC to +85ºC (at ambient humidity of 60 % max.) (with no icing or condensation) |
Ambient operating humidity
|
85 % max.(for +5ºC to +35ºC) |
Weight
|
Approx. 0.02 g |
Note: | The data given above are initial values. |
*1 The given values apply for Total Travel Position. Close or open circuit of the contact is 1ms max. | |
*2 For testing conditions, consult your OMRON sales representative. |
|
||||||||||||||||||||
Dimensions (Unit: mm)
|
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
(Unit: mm)
|
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
Caution
●Electrical Ratings
Confirm the contact load in order to select an appropriate switch rating.
Do not apply an excessive electrical load to the contacts, otherwise the contacts may weld, resulting in a short circuit or burning.
●Terminal Connection
Do not use flow soldering or hand soldering to solder terminals.
Conduct reflow soldering within the range shown in the terminal temperature profile below.
Some reflow soldering devices have extremely high peak values. Do a test in advance to confirm proper soldering conditions.
Do not conduct reflow soldering more than twice. Also provide a time interval of at least five minutes between the first and second reflow soldering processes to allow the Switch to return to room temperature. Heating the Switch continuously (without an interval) may cause the edges of the Switch to melt and degrade the characteristics.
When printing for a cream solder process, a 0.13 mm screen thickness is recommended.
Be sure to provide local ventilation.
●Printed Circuit Boards
Special attention must be paid to the handling of printed circuit boards after a Switch has been mounted onto them. Airborne PCB particles may penetrate the interior of the Switch when printed circuit boards are separated by cutting. Also, do not stack printed circuit boards that have Switches mounted on them.
●Product Specification Details
This document provides only a partial list of specifications. It is recommended that you request complete drawings and specifications prior to purchasing or using the product.
Correct Use
●Mounting
The cover has the same electric potential as the COM terminal. Do not short-circuit the cover with a NO or NC terminal when mounting the cover.
Be careful of the following points. Incorrect handling may lead to insufficient actuator return, Switch damage, or reduced durability.
- Set the operating body in line with the direction of the actuator movement, and make sure that the operating body is completely separate from the actuator when the Switch is in the free position (FP). When the actuator is operated from the crosswise direction of the Switch, make sure that the corner of the operating body has a minimum radius of R1.
- Set the Switch stroke to 70% to 100% of the overtravel (the difference between the operating position and the total travel position).
- Do not subject the Switch to operations that involve strong impact.
- Do not use the Switch as a stopper.
- Do not apply excessive loads to the cover or operate the actuator from a direction other than a specified operating direction.
- Do not use an adhesive to secure the Switch.
A lubricant is used in the Switch. Some of the lubricant may seep out because the Switch does not have an airtight construction. Consider this possibility with respect to the usage conditions when designing or using the Switch.
●Application Environment
Do not use the Switch in locations that are subject to toxic gas, silicon, excessive dust, excessive dirt, high temperatures, high humidity, sudden temperature changes, water splashes, or oil splashes.
Otherwise, damage resulting by faulty contact of the Switch contacts, corrosion, or other causes, or other functional faults may occur.
●Insulation and Wiring
Be sure that the installation conditions provide a sufficient insula- tion distance between Switch terminals and other metal parts, lands, etc.
●Cleaning
The Switch does not have an airtight construction, and it must not be cleaned with cleaning fluids. Malfunctions may occur if the cleaning fluid penetrates the interior of the Switch together with flux or foreign matter from the surface of the PCB.
●Confirmation with Actual Equipment
Be sure to confirm the quality of the product under the load and environmental conditions that will be used during actual applications.