Product Details Portlet
Miniature and Low Height
G6QE PCB Power Relay
Miniature and Low Height
Single-pole Power Relay
with 36A Switching Current
- High switching current of 36 A@250 VAC and 10,000 operations, 30 A@250 VAC and 100,000 operations in a miniature package
- Achieved 10-kV impulse withstand voltage (between coil and contacts)
- Power consumption reduced to 12% compared with rated coil consumption by lowering the applied voltage to the coil after applying nominal voltage for 100 ms relay operation (Reduced to 35% from rated coil voltage)
- Conforms to cULus, EN and CQC
RoHS Compliant
Model | 2D/3D CAD | |
---|---|---|
G6QE-1A | Download |

Note: This web page provides an excerpt from a datasheet. Refer to Product Datasheet and other applicable documents for more information.
Terminal Shape | Classification | Contact Form | Enclosure rating | Model | Rated coil voltage | Minimum packing unit |
---|---|---|---|---|---|---|
PCB terminals | Standard | SPST-NO (1a) | Flux protection | G6QE-1A | 5VDC 12VDC 24VDC |
50pcs/tray |

Coil Ratings
Contact
Characteristics
Rated Voltage | Rated current (mA) |
Coil resistance (Ω) |
Must operate voltage (V) |
Must release voltage (V) |
Max. voltage (V) |
Power consumption (mW) |
|
---|---|---|---|---|---|---|---|
% of rated voltage | |||||||
DC 5 | 280 | 17.9 | 70% max. | 5 to 23% | 140% (at 23ºC) |
Approx. 1400 Approx. 172 * |
|
DC 12 | 116.7 | 102.9 | |||||
DC 24 | 58.3 | 411.4 |
Note: | 1. | The rated current and resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. |
2. | The operating characteristics are measured at a coil temperature of 23°C. | |
3. | The maximum permissible voltage is the maximum value of the fluctuation range for the Relay coil operating power supply and was measured at an ambient temperature of 23°C. | |
* | Power consumption with Holding Voltage is approx.172 mW (when applying Holding Voltage at 35%). Please confirm the detail in page 3 Coil Voltage Reduction (Holding Voltage). |
Contact
Contact type | Single | |
---|---|---|
Contact material | Ag Alloy (Cd free) | |
Rated load | 36 A at 250 VAC (Resistive Load) 32 A at 250 VAC (Resistive Load) 30 A at 250 VAC (Resistive Load) |
|
Rated carry current | 36 A | |
Max. switching voltage | AC 277 V | |
Max. switching current | AC: 36 A |
Characteristics
Contact resistance *1 | 100 m Ω max. | |
---|---|---|
Operate time | 20 ms max. | |
Release time | 10 ms max. | |
Insulation resistance *2 | 1000 MΩ min. | |
Dielectric strength | Between coil and contacts | 4,500 VAC, 50/60 Hz for 1 min |
Between contacts of the same polarity | 2,000 VAC, 50/60 Hz for 1 min | |
Insulation distance | Between coil and contacts | Clearance: 3.2 mm, Creepage: 6.4 mm |
Impulse withstand voltage | Between coil and contacts | 10 kV (1.2×50μs) |
Vibration resistance | Destruction | 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) |
Malfunction | 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) |
|
Shock resistance | Destruction | 1,000 m/s2 |
Malfunction | 200 m/s2 | |
Durability | Mechanical | 1,000,000 operations min. (at 18,000 operations/h) |
Electrical | 100,000 operations min. (30 A, 250 VAC, resistive load) 50,000 operations min. (32 A, 250 VAC, resistive load) 10,000 operations min. (36 A, 250 VAC, resistive load) (ON for 1 s and OFF for 9 s) |
|
Failure rate (P level) (reference value) *3 | 100 mA at 5 VDC | |
Coil holding voltage *4 | 35% to 80% of rated coil voltage (contact carrying current 32 A, at 85 °C) 35% to 50% of rated coil voltage (contact carrying current 36 A, at 85 °C) |
|
Ambient operating temperature | -40°C to +60°C (when applying Rated Coil Voltage) -40°C to +85°C (contact carrying current 32 A, when applying Holding Voltage at 35% to 80%) (contact carrying current 36 A, when applying Holding Voltage at 35% to 50%) (with no icing or condensation) |
|
Ambient operating humidity | 5% to 85% | |
Weight | Approx. 17 g |
Note. | The values given above are initial values. | |
*1. | Measurement conditions: 5 VDC, 1 A, voltage drop method. |
|
*2. | Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. |
|
*3. | This value was measured at a switching frequency of 120 operations/min. | |
*4. | Power consumption with Holding Voltage is approx.172 mW (when applying Holding Voltage at 35%). Please confirm the detail in page 3 Coil Voltage Reduction (Holding Voltage). |
G6QE-1A ![]() |
|
PCB Mounting Holes (BOTTOM VIEW) ![]() |
Terminal Arrangement/ Internal Connections |
|