Product Details Portlet
G3VM-201H1 MOS FET Relays
MOS FET Relays Designed for Switching Minute Signals and Analog Signals.
- Continuous load current of 200 mA.
RoHS Compliant
- English
Datasheet
- English
Mosfet Selection
- English
MOS FET Relay General Catalog
- Japanese
データシート
- Chinese
目录
Model | 2D/3D CAD | |
---|---|---|
G3VM-201H1 | Download |

Note: This web page provides an excerpt from a datasheet. Refer to Product Datasheet and other applicable documents for more information.
Package type | Contact form | Terminals | Load voltage (peak value)* | Model | Minimum package quantity | |
---|---|---|---|---|---|---|
Number per tube | Number per tape and reel | |||||
SOP6 | 1a (SPST-NO) |
Surface-mounting terminals | 200 V | G3VM-201H1 | 75 | --- |
3VM-201H1(TR) | --- | 2,500 |
* The AC peak and DC value are given for the load voltage. |
Absolute Maximum Ratings (Ta = 25ºC)
Absolute Maximum Ratings (Ta = 25ºC)

Electrical Characteristics (Ta = 25ºC)
Item | Symbol | Rating | Unit | Measurement Conditions | ||
---|---|---|---|---|---|---|
Input | LED forward current | IF | 50 | mA | ||
LED forward current reduction rate | △IF/℃ | -0.5 | mA/ºC | Ta≥25ºC | ||
LED reverse voltage | VR | 5 | V | |||
Connection temperature | TJ | 125 | ºC | |||
Output | Load voltage (AC peak/DC) | VOFF | 200 | V | ||
Continuous load current | Connection A | IO | 200 | mA | Connection A: AC peak/DC Connection B and C: DC |
|
Connection B | 200 | |||||
Connection C | 400 | |||||
ON current reduction rate | Connection A | △IO/℃ | -2.0 | mA/ºC | Ta≥25ºC | |
Connection B | -2.0 | |||||
Connection C | -4.0 | |||||
Connection temperature | TJ | 125 | ºC | |||
Dielectric strength between I/O (See note 1.) | VI-O | 1,500 | Vrms | AC for 1 min | ||
Ambient operating temperature | Ta | -40 to +85 | ºC | With no icing or condensation | ||
Ambient storage temperature | Tstg | -55 to +125 | ºC | With no icing or condensation | ||
Soldering temperature | — | 260 | ºC | 10s |
Note: | 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. |
Absolute Maximum Ratings (Ta = 25ºC)

Electrical Characteristics (Ta = 25ºC)
Item | Symbol | Minimum | Typical | Maximum | Unit | Measurement conditions | ||
---|---|---|---|---|---|---|---|---|
Input | LED forward voltage | VF | 1.0 | 1.15 | 1.3 | V | IF=10mA | |
Reverse current | IR | --- | --- | 10 | µA | VR=5V | ||
Capacitance between terminals | CT | --- | 30 | --- | pF | V=0, f=1MHz | ||
Trigger LED forward current | IFT | --- | 1 | 3 | mA | Io=200mA | ||
Output | Maximum resistance with output ON | Connection A | RON | --- | 5 | 8 | Ω | IF=5mA, IO=200mA |
Connection B | --- | 3 | 5 | Ω | IF=5mA, IO=200mA | |||
Connection C | --- | 1.5 | --- | Ω | IF=5mA, IO=400mA | |||
Current leakage when the relay is open | ILEAK | --- | --- | 1.0 | µA | VOFF=200V | ||
Capacitance between terminals | COFF | --- | 100 | --- | pF | V = 0, f = 1 MHz | ||
Capacitance between I/O terminals | CI-O | --- | 0.8 | --- | pF | f=1MHz, Vs=0V | ||
Insulation resistance between I/O terminals | RI-O | 1,000 | 108 | --- | MΩ | VI-O=500VDC, ≤60% | ||
Turn-ON time | tON | --- | 0.6 | 1.5 | ms | IF=5mA, RL=200Ω, V DD=20V (See note 2.) | ||
Turn-OFF time | tOFF | --- | 0.1 | 1.0 | ms |
Note: 1. | Turn-ON and Turn-OFF Times![]() |
Note: 2. | These value are for Relays with NC contacts |
Surface-mounting Terminals Weight: 0.13 g ![]() Note: The actual product is marked differently from the image shown here. |
Actual Mounting Pad Dimensions (Recommended Value, Top View) ![]() |
Terminal Arrangement/Internal Connections![]() |
Note: The actual product is marked differently from the image shown here. |