Product Details Portlet
With Input Resistance
Without Input Resista
Connecting Socket
With Input Resistance
Without Input Resistance

G3DZ Solid State Relays
SSR Identical to the G6D in Size with AC/DC dual-use type and DC-only Type Available for the Whole Product Line
- 10-µA current leakage max. between open output terminals.
- 2,500-VAC dielectric strength ensured between input and output terminals.
- With or without input resistor incorporated models available.
- Incorporated with overvoltage absorption circuit.
- Full-wave rectified and half-wave rectified AC current switchable.
RoHS Compliant
Note: This web page provides an excerpt from a datasheet. Refer to Product Datasheet and other applicable documents for more information.
List of Models
scroll
Isolation | Zero cross function | Indicator | Rated output load | Rated input voltage | Model | Minimum packing unit |
---|---|---|---|---|---|---|
Photo-voltage coupler | No | No | 0.6 A 5 to 240 VAC 5 to 100 VDC |
5 VDC | G3DZ-2R6PL | 25 pcs |
12 VDC | ||||||
24 VDC | ||||||
0.5 A 5 to 100 VAC 5 to 100 VDC |
5 VDC | G3DZ-1R5PL | ||||
12 VDC | ||||||
24 VDC | ||||||
2.0 A 5 to 24 VDC |
5 VDC | G3DZ-DZ02P | ||||
12 VDC | ||||||
24 VDC |
scroll
Isolation | Zero cross function | Indicator | Rated output load | Max. input current | Model | Minimum packing unit |
---|---|---|---|---|---|---|
Photo-voltage coupler | No | No | 0.5 A 3 to 125 VAC 3 to 125 VDC |
50 mA (DC input) | G3DZ-1R5PLG | 25 pcs |
2.0 A 3 to 26.4 VDC |
G3DZ-DZ02PG |
Applicable Relay | Model |
---|---|
G3DZ-□ | P6D-04P |
Ratings
scroll
Item | Model | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
G3DZ-2R6PL | G3DZ-1R5PL | G3DZ-DZ02P | |||||||||
Input | Rated voltage | 5 VDC | 12 VDC | 24 VDC | 5 VDC | 12 VDC | 24 VDC | 5 VDC | 12 VDC | 24 VDC | |
Operating voltage | 4 to 6 VDC | 9.6 to 14.4 VDC | 19.2 to 28.8 VDC | 4 to 6 VDC | 9.6 to 14.4 VDC | 19.2 to 28.8 VDC | 4 to 6 VDC | 9.6 to 14.4 VDC | 19.2 to 28.8 VDC | ||
Impedance | 830 Ω ±20% | 2 kΩ ±20% | 4 kΩ ±20% | 750 Ω ±20% | 2 kΩ ±20% | 4 kΩ ±20% | 750 Ω ±20% | 2 kΩ ±20% | 4 kΩ ±20% | ||
Voltage level | Must operate voltage | 4 VDC max | 9.6 VDC max | 19.2 VDC max | 4 VDC max. | 9.6 VDC max. | 19.2 VDC max. | 4 VDC max. | 9.6 VDC max. | 19.2 VDC max. | |
Must release voltage | 1 VDC min. | ||||||||||
Output | Rated load voltage | 5 to 240 VAC 5 to 100 VDC |
5 to 100 VAC 5 to 100 VDC |
5 to 24 VDC | |||||||
Load voltage range | 3 to 264 VAC 3 to 125 VDC |
3 to 125 VAC 3 to 125 VDC |
3 to 26.4 VDC | ||||||||
Load current∗1 | AC: 100 µ to 0.6 A DC: 10 µ to 0.6 A |
AC: 100 μ to 0.5 A DC: 10 μ to 0.5 A |
DC: 10 μ to 2.0 A | ||||||||
Inrush current | 6 A (10 ms) | 5 A (10 ms) | 20 A (10 ms) |
scroll
Item | Symbol | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
G3DZ-1R5PLG | G3DZ-DZ02PG | ||||||||||
Input | Max. input current | IIN | 50 mA max. | ||||||||
Rated current | 6.25 mA (recommendation value) | ||||||||||
Must operate current | IOP | 4 mA max | |||||||||
Must release current | IRE | 0.6 mA max. | |||||||||
Input release voltage | VR | 3 V | |||||||||
Foward voltage | VF | 1.4 V (TYP) | |||||||||
Output | Load voltage range | 3 to 125 VAC 3 to 125 VDC |
3 to 26.4 VDC | ||||||||
Load current | 100 μ to 0.5 A | 100 μ to 2.0 A | |||||||||
Inrush current | 5 A (10 ms) | 20 A (10 ms) |
Characteristics
(at 25°C)
scroll
Item | Model | ||||
---|---|---|---|---|---|
G3DZ-2R6PL | G3DZ-1R5PL | G3DZ-1R5PLG | G3DZ-DZ02P | G3DZ-DZ02PG | |
Operate time∗1 | 6 ms max. | ||||
Release time∗1 | 10 ms max. | ||||
Output ON-resistance∗1 | 2.4 Ω max. | 3.0 Ω max. | 0.15 Ω max. | ||
Leakage current at OFF state | 10 μA max. (at 125 VDC) 100 μA max. (at 200 VAC) |
10 μA max. (at 125 VDC) 50 μA max. (at 100 VAC) |
10 μA max. (at 26.4 VDC) | ||
Insulation resistance | 100 MΩ min. (at 500 VDC) | ||||
Dielectric strength | 2,500 VAC, 50/60 Hz for 1 min between input and output | ||||
Vibration resistance | 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) | ||||
Shock resistance | 1,000 m/s2 | ||||
Storage temperature | −30°C to 100°C (with no icing or condensation) | ||||
Ambient operating temperature | −30°C to 85°C (with no icing or condensation) | ||||
Ambient operating humidity | 45% to 85%RH | ||||
Weight | Approx. 3.1 g | Approx. 2.8 g | Approx. 2.4 g | Approx. 2.6 g | Approx. 2.4 g |
Dimensions
(Unit: mm)
G3DZ-2R6PL / G3DZ-1R5PL(G) / G3DZ-DZ02P(G)
-
The above diagram is a G3DZ-2R6PL Relay
-
Mounting Holes (BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement / Internal Connections (BOTTOM VIEW)
-
G3DZ-2R6PL/-1R5PL(G)
-
G3DZ-DZ02P(G)
Safety Precautions
Precautions for Correct Use
Reversed Surge Voltage
-
If any reversed surge voltage is imposed on the input terminals, insert a diode in parallel to the input terminals. Do not impose a reversed voltage value of 3 V or more.
Terminals
-
Since terminals are made of materials with high heat conduction, complete soldering (automatic or manual) with 10 seconds at a temperature of 260°C. When fitting with a Socket, match properly and push straight down vertically.
Representative Example of Relay Driver Circuit
-
(For C-MOS) -
(For transistors)
Calculation of Input Resistance

SSR Mounting
-
Do not wash or solder the PCB while the SSR is mounted in the Socket.