Product Details Portlet
Contact Form (DPST-NO)
D2T Miniature Power / Door Switch
Door Switch Incorporated with Two Circuits for Power Loads and Micro Loads.
- Compact size, with two separate circuits for power and signals.
- Panel- or screw-mounted with ease.
RoHS Compliant
Note: This web page provides an excerpt from a datasheet. Refer to Product Datasheet and other applicable documents for more information.
Actuator(see note) | Right-angled solder terminals | Straight solder terminals |
---|---|---|
Pin plunger
|
D2T-T1 | D2T-T1S |
Hinge lever
|
D2T-LT1 | D2T-LT1S |
Contact Form (DPST-NO)
Ratings
Characteristics
|
Rated voltage | Resitive load |
---|---|---|
Between terminals 1 and 2
Between terminals 3 and 4 |
250VAC 125VAC |
5A 0.1 A |
Note: | The ratings values apply under the following trest conditions. | ||||||
|
Characteristics
Permissible operating speed
|
10 mm to 500 mm/s (pin plunger models) | ||||
---|---|---|---|---|---|
Permissible operating frequency
|
Mechanical: 120 operations /min max. Electrical: 30 operations /min max. |
||||
Insulation resistance
|
100 MΩ min. (at 500 VDC) | ||||
Contact resistance (initial value)
|
Between terminals 1 and 2: 50 mΩ max. Between terminals 3 and 4: 100 m Ω max. |
||||
Dielectric strength
|
1,000 VAC for 1 min 50/60 Hz between terminals of same polarity 1,500 VAC for 1 min 50/60 Hz between current-carrying metal part and ground (see note 1), between each terminal and non-current-carrying metal part, and between terminals of different polarity |
||||
Vibration resistance *1
|
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude | ||||
Shock resistance
|
Destruction:1,000m/s2{approx.100G} max. Malfunction *1: 300 m/s2 {approx. 30G} max. |
||||
Durability *2
|
|
||||
Degree of protection
|
IEC IP 40 | ||||
Degree of protection against electric shock
|
Class I | ||||
Proof tracking index (PTI)
|
175 | ||||
Ambient operating temperature
|
-25ºC to +85ºC (at ambient humidity of 60% max.) (with no icing or condensation) |
||||
Ambient operating humidity
|
85% max. (for +5ºC to +35ºC) | ||||
Weight
|
Approx. 10 g (pin plunger models) |
Note: | The data given above are initial values. | |
*1 | The values are at Free Position and Total Travel Position values for pin plunger, and Total Travel Position value for lever. Close or open circuit of the contact is 1 ms max. | |
*2 | For testing conditions, consult your OMRON sales representative. |
The illustrations and drawings are for right-angled terminals. Straight terminals are omitted.
Pin Plunger Models D2T-T1 D2T-T1S |
![]() |
||||||||
|
Hinge Lever Models D2T-LT1 D2T-LT1S |
![]() |
||||||||||||||
|
Correct Use
●Mounting
Apply operation force to the pin plunger in the direction it oper- ates.Applying forces laterally or from an oblique direction may damage the pin plunger.
Use M3 mounting screws to mount the Switch. Tighten the screws to a torque of 0.4 to 0.6 Nm {4 to 6 kgfcm}.
Soldering
Terminal connectiion
When soldering the lead wire to the terminal, first insert the lead wire conductor through the terminal hole and then conduct soldering.
Complete the soldering at the iron tip temperature not exceeding 350°C within 3 seconds, and do not apply any external force for 1 minute after soldering. Soldering at a excessively high temperature or soldering for more than 3 s may deteriorate the characteristics of the Switch.