D2AW-R Sealed Ultra Subminiature Basic Switch with Integrated Resistors

Detection of four states by internal resistor

  • <Output of four states>
    Four states (switch ON/OFF, short circuit, open circuit) are output.
  • Extra-long stroke even without levers. (OT reference value: 1.4 mm)
  • <Quiet operation>
    A sliding contact construction achieves high contact reliability and quiet operating sound.
RoHS Compliant
Model 2D/3D CAD ECAD(Download symbol,FootPrint,3DCAD)
* External site (Ultra Librarian) opens in a new window.
D2AW-R1-A003D Download Download
D2AW-R1-EL053FL Download Download
D2AW-R1-ER063FR Download Download
D2AW-R5-A003D Download Download
D2AW-R5-EL053FL Download Download
D2AW-R5-ER063FR Download Download
(*) Ultra Librarian uniquely created ECAD data based on the information provided by OMRON. Please note that OMRON does not guarantee the accuracy, concurrence or completeness of ECAD data.
Note: This web page provides an excerpt from a datasheet. Refer to Product Datasheet and other applicable documents for more information.

List of Models

scroll
Actuator Terminals Circuit structure Model

Without posts

Without posts

Short post on right

Short post on right

Short post on left

Short post on left

Pin plunger

Pin plunger
PCB terminals Series circuit D2AW-R1-A003D D2AW-R1-ER003D D2AW-R1-EL003D
Parallel circuit D2AW-R5-A003D D2AW-R5-ER003D D2AW-R5-EL003D
Press-fit terminals
(Right angled)
Series circuit D2AW-R1-A003FR D2AW-R1-ER003FR ---
Parallel circuit D2AW-R5-A003FR D2AW-R5-ER003FR ---
Press-fit terminals
(Left angled)
Series circuit D2AW-R1-A003FL --- D2AW-R1-EL003FL
Parallel circuit D2AW-R5-A003FL --- D2AW-R5-EL003FL

Long straight leaf lever

Long straight leaf lever
PCB terminals Series circuit D2AW-R1-A053D D2AW-R1-ER053D D2AW-R1-EL053D
Parallel circuit D2AW-R5-A053D D2AW-R5-ER053D D2AW-R5-EL053D
Press-fit terminals
(Right angled)
Series circuit D2AW-R1-A053FR D2AW-R1-ER053FR ---
Parallel circuit D2AW-R5-A053FR D2AW-R5-ER053FR ---
Press-fit terminals
(Left angled)
Series circuit D2AW-R1-A053FL --- D2AW-R1-EL053FL
Parallel circuit D2AW-R5-A053FL --- D2AW-R5-EL053FL

Leaf lever

Leaf lever
PCB terminals Series circuit D2AW-R1-A063D D2AW-R1-ER063D D2AW-R1-EL063D
Parallel circuit D2AW-R5-A063D D2AW-R5-ER063D D2AW-R5-EL063D
Press-fit terminals
(Right angled)
Series circuit D2AW-R1-A063FR D2AW-R1-ER063FR ---
Parallel circuit D2AW-R5-A063FR D2AW-R5-ER063FR ---
Press-fit terminals
(Left angled)
Series circuit D2AW-R1-A063FL --- D2AW-R1-EL063FL
Parallel circuit D2AW-R5-A063FL --- D2AW-R5-EL063FL

If you have any desired model with a specification not in the above list, contact your OMRON sales representative. We will consider if a requested model can be manufactured by modifying existing models.

Characteristics

Permissible operating speed 30 to 500 mm/s (pin plunger models)
Permissible operating frequency Mechanical 30 operations/min max.
Electrical 20 operations/min max
Vibration resistance*1 Malfunction Frequency: 10 to 55 Hz
Amplitude: 1.5 mm
Direction Time: X,Y and Z 10 minutes per axis
Shock resistance*1 Destruction Shock: MAX 1000m/s2
Direction Time: X,Y and Z 10 times per axis
Malfunction Shock: MAX 300m/2
Direction Time: X,Y and Z 3 times per axis
Durability*2 Mechanical 200,000 operations min. (30 operations/min)
Electrical 200,000 operations min. (20 operations/min)
Degree of protection IEC IP67
Heart resistant 85°C 500 hours
Cold resistant -40°C 500 hours
Humidity resistance 70°C 95%RH 500 hours
Temperature cycle resistance -40°C (12 hours <--> 55°C (12 hours) 5 cycles
Weight Approx. 0.7 g (for pin plunger models with terminals)

Dimensions / Operating Characteristics

(Unit: mm)

The following illustrations and drawings are for solder terminal models. PCB terminal models are omitted from the drawings. Refer to Terminals for these terminals.
When ordering, replace □ with the code for the rating that you need. For the combination of models, refer to List of Models.

Pin plunger

D2AW-R□-□003□
D2AW-R□-□003□
Operating characteristics Type
Without posts Models with posts
Operating Force OF Max. 1.0N {101 gf}
Releasing Force RF Min. 0.1N {10 gf}
Overtravel OT 1.4 mm (reference value)
Movement Differential MD Max. 0.25 mm
Free Position FP Max. 11.2 mm 7.2 mm
Operating Position OP 10.4 ± 0.3 mm 6.4 ± 0.3 mm
Total Travel Position TTP Max. 9.1 mm 5.1 mm

Long straight leaf lever

D2AW-R□-□053□
D2AW-R□-□053□
Operating characteristics Type
Without posts Models with posts
Operating Force OF Max. 1.5N {152 gf}
Releasing Force RF Min. 0.1N {10 gf}
Overtravel OT 2.5 mm (reference value)
Movement Differential MD Max. 0.7 mm
Free Position FP Max. 15.9 mm 11.9 mm
Operating Position OP 12.1 ± 0.8 mm 8.1 ± 0.8 mm
Total Travel Position TTP Max. 10.0 mm 6.0 mm

Leaf lever

D2AW-R□-□063□
D2AW-R□-□063□
Operating characteristics Type
Without posts Models with posts
Operating Force OF Max. 2.0N {203 gf}
Releasing Force RF Min. 0.2N {20 gf}
Overtravel OT 1.8 mm (reference value)
Movement Differential MD Max. 0.5 mm
Free Position FP Max. 13.3 mm 9.3 mm
Operating Position OP 11.4 ± 0.5 mm 7.4 ± 0.5 mm
Total Travel Position TTP Max. 9.8 mm 5.8 mm

Safety Precautions

Cautions

Degree of Protection
  • Do not use this product underwater.
    Although molded lead wire models satisfy the test conditions for the standard given below, this test is to check the ingress of water into the switch enclosure after submerging the Switch in water for a given time. Satisfying this test condition does not mean that the Switch can be used underwater.

    • JIS C0920 : Degrees of protection provided by enclosures of electrical apparatus (IP Code)
    • IEC 60529 : Degrees of protection provided by enclosures (IP Code)
    • Degree of protection : IP67(check water intrusion after immersion for 30 min. submerged 1m underwater)
  • Do not operate the Switch when it is exposed to water spray, or when water drops adhere to the Switch surface, or during sudden temperature changes, otherwise water may intrude into the interior of the Switch due to a suction effect.
  • Prevent the Switch from coming into contact with oil and chemicals.
    Otherwise, damage to or deterioration of Switch materials may result.
  • Do not use the Switch in areas where it is exposed to silicon adhesives, oil, or grease. Otherwise faulty contact may result due to the generation of silicon oxide.
Side-actuated (Cam/Dog) Operation
  • When using a cam or dog to operate the Switch, factors such as the operating speed, operating frequency, push-button indentation, and material and shape of the cam or dog will affect the durability of the Switch. Confirm performance specifications under actual operating conditions before using the Switch in applications.

Correct Use

Mounting
  • Turn OFF the power supply before mounting or removing the Switch, wiring, or performing maintenance or inspection. Failure to do so may result in electric shock or burning.
  • For models with posts, secure the posts by pressing into an attached device. Provide guides on the opposite ends of the posts to ensure that they do not fall out or rattle.
  • When mounting a Press-fit terminals, press in A (body) and B (terminal) in the drawing below at the same time.
    If A (body) only is pressed in, the Press-fit terminals will be deformed and will not be properly inserted.
    Also, ensure that the Press-fit terminals is facing down when it is inserted.
    Avoid connecting soldered or laser-welded terminals.
    Avoid mounting in conditions exposed to corrosive gases, high temperature and humidity, and dust.

Operating Body
  • Use an operating body with low frictional resistance and of a shape that will not interfere with the sealing rubber, otherwise the plunger may be damaged or the sealing may deteriorate.
ESD
  • Static electricity adversely affects the chip resistor inside. For this reason, adopt sufficient electrostatic discharge measures when handling the Switch.
    Also, take sufficient consideration in the handling of the Switch and its packaging and transportation container.
Handling
  • Do not handle the Switch in a way that may cause damage to the sealing rubber.
  • When handling the Switch, ensure that pressure is not applied to the posts in the directions shown in the following diagram. Also, ensure that uneven pressure or pressure in a direction other than the operating direction is not applied to the Actuator as shown in the following diagram. Otherwise, the post, Actuator, or Switch may be damaged, or the service life may be reduced.